Validity and Reproducibility of a New Treadmill Protocol: The Fitkids Treadmill Test.

نویسندگان

  • Elles M W Kotte
  • Janke F DE Groot
  • Bart C Bongers
  • Alexander M F Winkler
  • Tim Takken
چکیده

PURPOSE This study aimed to investigate the validity and reproducibility of a new treadmill protocol in healthy children and adolescents: the Fitkids Treadmill Test (FTT). METHODS Sixty-eight healthy children and adolescents (6-18 yr) were randomly divided into a validity group (14 boys and 20 girls; mean ± SD age, 12.9 ± 3.6 yr) that performed the FTT and Bruce protocol, both with respiratory gas analysis within 2 wk, and a reproducibility group (19 boys and 15 girls; mean ± SD age, 13.5 ± 3.5 yr) that performed the FTT twice within 2 wk. A subgroup of 21 participants within the reproducibility group performed both FTT with respiratory gas analysis. Time to exhaustion (TTE) was the main outcome of the FTT. RESULTS V˙O2peak measured during the FTT showed excellent correlation with V˙O2peak measured during the Bruce protocol (r = 0.90; P < 0.01). Backward multiple regression analysis provided the following prediction equations for V˙O2peak (L·min) for boys and girls, respectively: V˙O2peak FTT = -0.748 + (0.117 × TTEFTT) + (0.032 × body mass) + 0.263, and V˙O2peak FTT = -0.748 + (0.117 × TTEFTT) + (0.032 × body mass) [R = 0.935; SEE = 0.256 L·min]. Cross-validation of the regression model showed an R value of 0.76. Reliability statistics for the FTT showed an intraclass correlation coefficient of 0.985 (95% confidence interval, 0.971-0.993; P < 0.001) for TTE. Bland-Altman analysis showed a mean bias of -0.07 min, with limits of agreement between +1.30 and -1.43 min. CONCLUSIONS Results suggest that the FTT is a useful treadmill protocol with good validity and reproducibility in healthy children and adolescents. Exercise performance on the FTT and body mass can be used to adequately predict V˙O2peak when respiratory gas analysis is not available.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fitkids exercise therapy program in the Netherlands.

PURPOSE To describe the demographics, medical diagnoses, and initial aerobic fitness levels of children participating in Fitkids: an exercise therapy program for children with chronic conditions or disabilities in the Netherlands. METHODS We reviewed data of children who were in the program on September 2010. RESULTS In total, 2482 children from 105 Fitkids centers were included. Results sh...

متن کامل

A new test for diagnosing vasovagal syncope: Standing after treadmill test with sublingual nitrate administration

INTRODUCTION Increased adrenergic tone might be an additional trigger of orthostatic stress of vasovagal syncope (VVS). Exercise before standing might provide increased sensitivity compared to standing using a sublingual nitroglycerines protocol during tilt table testing. The aim of this study was to evaluate the diagnostic value of treadmill testing before standing with nitroglycerin administr...

متن کامل

Effect of 50 grams increasing of sport shoes' weight on running economy in a 15 minuets running protocol on treadmill

Purpose: The aim of this study was to test the effect of 50 gr changes in sport shoes' weight on Vo2max and running economy during 15 minutes running protocol. Method: 15 active males (age of 24.60 ± 2.06; height of 178 ± 5.83 cm) were selected in this study. Subjects ittrcicitrap in a 15 minutes running protocol in three running speeds of 4, 6 and 8 km/h. Total time for each running speed was ...

متن کامل

Computerized Dual-Task Testing of Gait and Visuospatial Cognitive Functions; Test-Retest Reliability and Validity

The common occurrence of age decline in mobility and cognition does cause a decrease in the level of physical activity and an increased falls risk. Consequently, dual -task (DT) assessment that simultaneously addresses both mobility skills and cognitive functions are important because, continued difficulties and fall injuries will have a sizable impact in this population. The first objective of...

متن کامل

Novel exercise protocol suitable for use on a treadmill or a bicycle ergometer.

Many exercise protocols are in use in clinical cardiology, but no single test is applicable to the wide range of patients' exercise capacity. A new protocol was devised that starts at a low workload and increases by 15% of the previous workload every minute. This is the first protocol to be based on exponential rather than linear increments in workload. The new protocol (standardised exponentia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medicine and science in sports and exercise

دوره 47 10  شماره 

صفحات  -