Bicuspid pulmonary valve implantation using polytetrafluoroethylene membrane: early results and assessment of the valve function by magnetic resonance imaging.
نویسندگان
چکیده
OBJECTIVES The durability of bioprosthetic valves in the pulmonary position is suboptimal. The objectives of this study were to evaluate the early results of polytetrafluoroethylene (PTFE) bicuspid pulmonary valve (PV) implantation and to better define the function of this valve by magnetic resonance imaging (MRI). METHODS Fifty-six patients who underwent PTFE bicuspid PV implantation between June 2009 and August 2011 were retrospectively analysed. The median age was 17.5 years and median valve size was 26 mm. Fundamental diagnoses were tetralogy of Fallot (n = 38), pulmonary atresia with ventricular septal defect (n = 8), double outlet right ventricle (n = 7) and absent PV syndrome (n = 3). Thirty-two patients with pulmonary regurgitation (PR) underwent MRI preoperatively and 22 of them underwent follow-up MRI at a median of 6.7 months postoperatively. RESULTS There was one early death. Postoperative echocardiography (n = 53) showed no or trivial PR in 49 patients and mild PR in 4. Median follow-up duration was 15.2 months. There was no late death or reoperation. Follow-up echocardiography (n = 41) performed at a median of 7.5 months postoperatively showed no or trivial PR in 33 patients and mild PR in 8 patients. Follow-up MRI showed a significant reduction in right ventricular volumes and improvement in biventricular function. The median PR fraction of this valve was 10%. CONCLUSIONS Early results of bicuspid PV implantation using PTFE membrane were satisfactory. PTFE bicuspid PV demonstrated excellent performance for the short term as evidenced by echocardiography and MRI. Long-term follow-up is mandatory to determine the durability of this valve.
منابع مشابه
Right ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease
Introduction: In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...
متن کاملBicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva
Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...
متن کاملHigh-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient
Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...
متن کاملEarly regression of left ventricular hypertrophy after aortic valve replacement by the Ross procedure detected by cine MRI.
AIM The primary objective of our study was to assess the time course of left ventricular remodeling after the Ross procedure with the use of cine magnetic resonance imaging (MRI). METHODS In a prospective study, 10 patients with isolated aortic valve disease were examined prior to aortic valve surgery, as well as at early follow-up (mean 4 weeks) and at late follow-up (mean 8 months) after pu...
متن کاملAssessment of acute changes in biventricular volumes, systolic function and strain after MitraClipTM-implantation using magnetic resonance imaging and feature tracking
Background MitraClipTM-implantation has been shown to significantly reduce mitral regurgitation (MR) in patients with high surgical risk. Whereas hemodynamic and echocardiographic studies suggest a reduction in left ventricular (LV) volumes and an increase in cardiac output following the intervention, there is very limited data on assessment of volumetric and functional changes after MitraClipT...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 43 3 شماره
صفحات -
تاریخ انتشار 2013