Does standoff material affect acoustic radiation force impulse elastography? A preclinical study of a modified elastography phantom
نویسندگان
چکیده
PURPOSE This study was conducted to determine the influence of standoff material on acoustic radiation force impulse (ARFI) measurements in an elasticity phantom by using two different probes. METHODS Using ARFI elastography, 10 observers measured the shear wave velocity (SWV, m/sec) in different lesions of an elasticity phantom with a convex 4C1 probe and a linear 9L4 probe. The experimental setup was expanded by the use of an interposed piece of porcine muscle as standoff material. The probe pressure on the phantom was registered. RESULTS Faulty ARFI measurements occurred more often when quantifying the hardest lesion (74.0 kPa 4.97 m/sec) by the 9L4 probe with the porcine muscle as a standoff material interposed between the probe and the phantom. The success rate for ARFI measurements in these series was 52.4%, compared with 99.5% in the other series. The SWV values measured with the 9L4 probe were significantly higher (3.33±1.39 m/sec vs. 2.60±0.74 m/sec, P<0.001 in the group without muscle) and were closer to the reference value than those measured with the 4C1 probe (0.25±0.23 m/sec vs. 0.85±1.21 m/sec, P<0.001 in the same group). The SWV values measured when using the muscle as a standoff material were lower than those without the muscle (significant for 9L4, P=0.040). The deviation from the reference value and the variance increased significantly with the 9L4 probe if the muscle was in situ (B=0.27, P=0.004 and B=0.32, P<0.001). In our study, the pressure exerted by the operator had no effect on the SWV values. CONCLUSION The presence of porcine muscle acting as a standoff material influenced the occurrence of failed measurements as well as the variance and the accuracy of the measured values. The linear high-frequency probe was particularly affected.
منابع مشابه
Ultrasound elastography for thyroid nodules: recent advances
Ultrasonography (US)-based elastography has been introduced as a noninvasive technique for evaluating thyroid nodules that encompasses a variety of approaches such as supersonic shear imaging and acoustic radiation force impulse imaging as well as real-time tissue elastography. However, the diagnostic performances for differentiating malignant thyroid nodules from benign ones with elastography ...
متن کاملTesticular microlithiasis and preliminary experience of acoustic radiation force impulse imaging
BACKGROUND Elastography of the testis can be used as a part of multiparametric examination of the scrotum. PURPOSE To determine the testicular stiffness using acoustic radiation force impulse imaging (ARFI) technique in men with testicular microlithiasis (TML). MATERIAL AND METHODS In 2013, 12 patients with diagnosed testicular microlithiasis in 2008 (mean age, 51 years; age range, 25-76 ye...
متن کاملPreclinical evaluation of acoustic radiation force impulse measurements in regions of heterogeneous elasticity
PURPOSE The purpose of this study was to compare the reliability of ultrasound-based shear wave elastography in regions of homogeneous versus heterogeneous elasticity by using two different probes. METHODS Using acoustic radiation force impulse (ARFI) elastography, we measured the shear wave velocity (SWV) in different lesions of an elastography phantom with the convex 4C1 probe and the linea...
متن کاملComparative study between two point Shear Wave Elastographic techniques: Acoustic Radiation Force Impulse (ARFI) elastography and ElastPQ.
AIM To compare the feasibility and the liver stiffness (LS) values obtained by means of the two available point Shear Wave Elastographic (pSWE) techniques: ARFI elastography and ElastPQ technique. MATERIAL AND METHODS Our study included 176 subjects with or without chronic liver disease, in which LS was evaluated in the same session by means of ARFI elastography and ElastPQ. RESULTS Ten val...
متن کاملThe safety and feasibility of diagnostic acoustic radiation force impulse elastography used for eyes. A preliminary in vivo study.
AIMS To assess the safety and feasibility of acoustic radiation force impulse (ARFI) elastography in the eyes of rats. Material and methods: One hundred and twenty-six SD rats were divided into 7 groups. Group 1 was the control group and Group 2 to Group 7 were investigated by ARFI elastography using increased powers of 5%, 10%, 20%, 50%, and 100% and repetitions of 5 or 10. The changes of ocul...
متن کامل