Comparison of the remaining dentin thickness in the root after hand and four rotary instrumentation techniques: an in vitro study.

نویسندگان

  • M S Rama Rao
  • Abdul Shameem
  • Rashmi Nair
  • Sureshbabu Ghanta
  • Rekha P Thankachan
  • Johnson K Issac
چکیده

AIM The aim of the present study was to compare the remaining dental thickness (RDT) in the mesiobuccal root of mandibular first molars at 3 and 7 mm from the anatomic apex after instrumentation with ProTaper, light speed LSX, K3 and M2 and to compare with that of K-files. MATERIALS AND METHODS In this study, 60 extracted, untreated human mandibular first molars with fully formed apices, with curvature less than 35° and no root resorption were used. Prepared specimens were cut horizontally at 3 and 7 mm short of anatomic apex. The least dentin thickness from canal to external root surface was observed under 3× magnification and recorded using Clemax measuring tool and the sections were reassembled. Group I-instrumentation with ProTaper, group II-instrumentation with K3, group III-instrumentation with Light Speed LSX, group IV-instrumentation with M2 and group V- instrumentation with K-files and RDT was measured. RESULTS Results showed that group V removed lesser amount of dentin compared to all other groups while all the three instrumentation techniques removed almost equal amount of dentin apically. CLINICAL SIGNIFICANCE Cleaning and shaping of the root canal space involves the elimination of pathogenic contents as well as attaining a uniform specific shape. However, the RDT following the use of various intraradicular procedures is an important factor to be considered as an iatrogenic cause that may result in root fracture. To avoid this, newer rotary instruments are being introduced.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of remaining obturating material on canal walls using rotary and hand instrumentation techniques for endodontic re-treatment

Comparison of remaining obturating material on canal walls using rotary and hand instrumentation techniques for endodontic re-treatment Dr. J. Ghoddusi*- Dr. P. Ghaziani*- Dr. Sh. Nazari** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Mashhad University of Medical Sciences. **Assistant Professor of Endodontics Dept., Faculty of Dentistry, Hamedan University of Medical Science...

متن کامل

Comparison of the Effect of ProTaper and Gates-Glidden Drills On the Remaining Root Dentin Thickness at the Coronal Region of the Root

Background and Aim: The purpose of this study was to evaluate residual dentin thickness of the root and the area of the canal lumen in the coronal region of the mesiobuccal and mesiolingual canals of the lower first molars after canal preparation with the common method of using hand files and Gates Glidden drills or ProTaper rotary files, by Spiral Ct-Scan. Materials and Methods: In this exp...

متن کامل

A comparison of apically extruded debris between conventional and 2 rotary instrumentation techniques according to the number of applications(An in vitro study)

A comparison of apically extruded debris between conventional and 2 rotary instrumentation techniques according to the number of applications(An in vitro study) Dr. MH. Zarabi* - Dr. H. Djafarzadeh** - Dr. M. Bidar** *- Associate Professor of Endodontics Dept. - Faculty of Dentistry – Mashhad University of Medical Sciences. **- Endodontist. Background and Aim: Various kinds of hand or rotary te...

متن کامل

Comparison of removed dentin thickness with hand and rotary instruments

INTRODUCTION The aim of this study was to evaluate the amount of dentine removed after canal preparation using stainless steel (SS) hand instruments or rotary ProFile instruments. MATERIALS AND METHODS Thirty-six extracted human teeth with root canal curvatures less than 30º were embedded in clear polyester resin. The roots were cut horizontally at apical 2, 4 and 7 mm. Dentin thickness was m...

متن کامل

Comparison of apically extruded debris and instrumentation time using rotary, endodontic handpiece and hand files in primary molar teeth: (In-vitro )

Abstract Background & Aim : This study was aimed to compare the instrumentation time and the amount of debris extruded apically  during root canal preparation using hand files ,Mtwo rotary system and endodontic handpiece  in primary molar teeth. Method & Material : In this experimental study, sixty roots of  primary molars of human teeth were assigned to three groups (for each group, n=20). The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 14 4  شماره 

صفحات  -

تاریخ انتشار 2013