Design of occlusion pressure testing system for infu-sion pump
نویسندگان
چکیده
Reliability of medical devices such as infusion pumps is extremely important because these devices are being used in patients who are in critical condition. Occlusion pressure, as an important parameter of infusion pumps, should be detected when an occlusion occurred. However, infusion pumps’ occlusion pressure could not be tested and the performance of these pumps is not known to us. In order to test the occlusion pressure of infusion pump, a testing system has been put forward according to standards of IEC 60601-2-24:1998/ GB 9706.272005. The system is comprised of sensor, acquisition card, three-way tap and so on; this system is controlled by a PC. At the same time, sampling rate could be changed if necessary and test time could be recorded. And then the characteristics of this system were studied, such as linear, effects of pump rates and different pumps. The system remained linear in a given environment. The higher is the pump rate, the faster is the time to reach occlusion condition. The testing system has been proved to be effective in testing the occlusion pressure of infusion pumps and the accuracy error of pressure is content the demand of ±1% of range.
منابع مشابه
Numerical Investigation on the Effect of Mold Design on Shrinkage of Sand Casted Multistage BB3-6×6 Pump Casing (RESEARCH NOTE)
Design and manufacturing technology of high pressure multistage pumps which are commonly utilized in oil and gas industries, used to be imported from foreign companies. Due to international sanctions against I. R. Iran, it started to be designed and launched domestically. Nowadays all production lines including design, manufacturing and testing of these pumps have been performed by Iranian expe...
متن کاملA Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform
Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...
متن کاملInnovative Methodology Electrohydraulic pump-driven closed-loop blood pressure-regulatory system
Siu KL, Ahn JM, Chon KH. Electrohydraulic pump-driven closed-loop blood pressure regulatory system. Am J Physiol Renal Physiol 296: F1530–F1536, 2009. First published April 9, 2009; doi:10.1152/ajprenal.90756.2008.—In this paper, we describe our design for a new electrohydraulic (EH) pump-driven renal perfusion pressure (RPP)-regulatory system capable of implementing precise and rapid RPP regul...
متن کاملElectrohydraulic pump-driven closed-loop blood pressure-regulatory system.
In this paper, we describe our design for a new electrohydraulic (EH) pump-driven renal perfusion pressure (RPP)-regulatory system capable of implementing precise and rapid RPP regulation in experimental animals. Without this automated system, RPP is manually controlled via a blood pressure clamp, and the imprecision in this method leads to compromised RPP data. This motivated us to develop an ...
متن کامل01 The conceptual design of the photovoltaic solar thermal collector hybrid system and the ground source heat pump to provide electricity, heating and cooling a residential building focusing on technical, economic and environmental parameters.
This paper attempts to present and compare four solar assisted ground source heat pump combined systems with series and parallel layouts and direct and indirect heat exchange in Zahedan in order to supply part of the electricity demand for equipment and selling surplus electricity to the grid as a source of project financing and revenue generation for residents, moreover, fulfill the region's n...
متن کامل