Fully Automatic Skull-Stripping in 3D Time-of-Flight MRA Image Sequences

نویسندگان

  • Nils Daniel Forkert
  • Dennis Säring
  • Jens Fiehler
  • Till Illies
  • Matthias Färber
  • Dietmar P. F. Möller
  • Heinz Handels
چکیده

In this paper we present a robust skull-stripping method for the isolation of cerebral tissue in 3D Time-of-Flight (TOF) magnetic resonance angiographic images of the brain. 3D TOF images are often acquired in case of cerebral vascular diseases, because of their good blood-to-background-contrast. Skull-stripping is an essential preprocessing step towards a better segmentation as well as direct visualization of the vascular system. Our approach consists of three main steps. After preprocessing in order to reduce signal inhomogeneities and noise the first main step is the segmentation of the surrounding skull using a region growing approach. The second step is the automatic extraction of distinctive points at the border of the brain, based on the segmentation of the skull, which are then used as supporting points for a graph based contour extraction. The third step is a slicewise correction based on a non-linear registration in order to improve sub-optimal segmentation results. The method proposed was validated using 18 manually stripped datasets. The calculated similarity measures show that the proposed method leads to good segmentation results with only a few segmentation errors. At the same time the mean rate of vessel voxels included by the brain segmentation is 99.18%. In summary the procedure suggested allows a fast and fully automatic segmentation of the brain and is especially helpful as a preprocessing step towards an automatic segmentation of the vessel system or direct volume rendering.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fuzzy-Based Extraction of Vascular Structures from Time-of-Flight MR Images

In this paper an automatic fuzzy based method for the extraction of the cerebrovascular system from 3D Time-of-Flight (TOF) MRA image sequences is presented. In order to exclude non-brain tissue an automatic skull stripping method is applied in a preprocessing step. Based on the TOF images vesselness and maximum parameter images are computed first. These parameter images are then combined with ...

متن کامل

Follow-up of coiled cerebral aneurysms at 3T: comparison of 3D time-of-flight MR angiography and contrast-enhanced MR angiography.

BACKGROUND AND PURPOSE Our aim was to compare contrast-enhanced MR angiography (CE-MRA) and 3D time-of-flight (TOF) MRA at 3T for follow-up of coiled cerebral aneurysms. MATERIALS AND METHODS Fifty-two patients treated with Guglielmi detachable coils for 54 cerebral aneurysms were evaluated at 3T MRA. 3D TOF MRA (TR/TE = 23/3.5; SENSE factor = 2.5) and CE-MRA by using a 3D ultrafast gradient-...

متن کامل

Skull Stripping of Mri Head Scans Based on Chan-vese Active Contour Model

Whole brain segmentation referred as skull stripping, it is an important process in neuriomage analysis. Automatic segmentation of brain tissues from magnetic resonance images (MRI) remains a challenging task due to variation in shape and size, use of different pulse sequences, overlapping signal intensities and imaging artifacts. Level sets and active contour methods have tremendous potential ...

متن کامل

Skull Stripping from MRI of Head Scans based on 2D Region Growing

Skull stripping is a process of segmenting brain portion in MR brain images. It is an important image processing step in many neuroimage studies. In this paper, we propose a new skull stripping method for magnetic resonance image (MRI) of human head scans based on 2D region growing. This is a fully automatic method for segmenting the brain portion from T1, T2 and PD weighted MR images. The prop...

متن کامل

Non-Enhanced T1-Weighted Liver Vessel Imaging at 7 Tesla

OBJECTIVES Aim of the study was to assess the feasibility and to compare three non-enhanced T1-weighted (w) sequences for liver vessel imaging at 7 Tesla (T). MATERIAL AND METHODS 12 healthy volunteers were examined on a 7 T whole-body MR-system. The following non-enhanced sequences were acquired: T1w 2D FLASH, T1w 3D FLASH and Time of flight (TOF)-MRA. Qualitative image analysis was performe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008