Successful CAVH in an austere environment using readily available disposable hospital supplies.
نویسندگان
چکیده
Care of the trauma victim with acute renal failure in resource-limited locations presents a number of challenges [1]. Lack of standard haemodialysis equipment, supplies and trained personnel; unreliable and/or unsafe water sources; and non-functional or unreliable electrical systems, are some of the factors that limit the ability to care for victims with renal failure requiring renal replacement therapy. Man-made or natural disasters, such as the 1999 Marmara earthquake in Turkey, may threaten to overwhelm existing local dialytic resources, if they remain functional at all [2]. The challenge is not limited to disasters in which patients develop de novo renal failure; the chronic dialysis population itself may require the immediate implementation of alternative renal replacement therapies if patients are unable to access haemodialysis centres or hospitals, as observed during the flooding of New Orleans in the aftermath of Hurricane Katrina in 2005 [3]. We present the case of a patient with myoglobinuric acute renal failure, who was successfully managed with continuous arteriovenous haemofiltration (CAVH) in a forward-deployed military hospital, using a circuit comprised of standard haemodialysis and peritoneal dialysis equipment, and other readily available hospital supplies. Although we cannot recommend this system for large-scale implementation without further testing, given its simplicity, low cost and ready availability, the circuit herein described may be useful for disaster management teams planning for the care of multiple renal patients in austere locations if standard systems fail or become dysfunctional.
منابع مشابه
Reducing medical waste.
Medical waste is a necessary by-product of any hospital environment; however, the majority of regulated medical waste is produced in the OR from the use of disposable surgical supplies (eg, drapes, gowns, basins, gloves, sponges). We conducted a concept comparison project in the ORs of two large medical centers in Bethesda, Maryland, and Washington, DC, to evaluate the effects of using reusable...
متن کاملUsability study of a novel, self-lighted, disposable speculum: military applications.
STUDY DESIGN Data collected from a postutilization questionnaire were used to evaluate the usability of the OfficeSPEC disposable vaginal speculum, specifically the effectiveness, efficiency, and acceptability, in clinical, hospital, and austere environments. RESULTS Usability data analysis showed the OfficeSPEC speculum had an effectiveness rating of 4.6/5, efficiency rating of 4.5/5, and ac...
متن کامل[Costs of reusable and disposable aprons in a public teaching hospital].
OBJECTIVE To analyze the direct cost of reusable and disposable aprons in a public teaching hospital. METHOD Cross-sectional study of quantitative approach, focusing on the direct cost of reusable and disposable aprons at a teaching hospital in northern Paraná. The study population consisted of secondary data collected in reports of the cost of services, laundry, materials and supplies divisi...
متن کاملMilitary Medicine Pain Management in Current Combat Operations
Pain management in the U.S. Military, particularly in combat, shares many of the same principles found in civilian heath care organizations and institutions. Pain is one of the most common reasons for which soldiers seek medical attention in the combat environment, which mirrors the civilian experience.However, the combat environment exacerbates the typical challenges found in treating acute pa...
متن کاملPoint-of-Care Ultrasound in Austere Environments: A Complete Review of Its Utilization, Pitfalls, and Technique for Common Applications in Austere Settings.
With the advent of portable ultrasound machines, point-of-care ultrasound (POCUS) has proven to be adaptable to a myriad of environments, including remote and austere settings, where other imaging modalities cannot be carried. Austere environments continue to pose special challenges to ultrasound equipment, but advances in equipment design and environment-specific care allow for its successful ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 22 4 شماره
صفحات -
تاریخ انتشار 2007