Pulse wave velocity with 4D flow MRI: systematic differences and age-related regional vascular stiffness.

نویسندگان

  • Petter Dyverfeldt
  • Tino Ebbers
  • Toste Länne
چکیده

PURPOSE The objective of this study was to compare multiple methods for estimation of PWV from 4D flow MRI velocity data and to investigate if 4D flow MRI-based PWV estimation with piecewise linear regression modeling of travel-distance vs. travel time is sufficient to discern age-related regional differences in PWV. METHODS 4D flow MRI velocity data were acquired in 8 young and 8 older (age: 23±2 vs. 58±2 years old) normal volunteers. Travel-time and travel-distance were measured throughout the aorta and piecewise linear regression was used to measure global PWV in the descending aorta and regional PWV in three equally sized segments between the top of the aortic arch and the renal arteries. Six different methods for extracting travel-time were compared. RESULTS Methods for estimation of travel-time that use information about the whole flow waveform systematically overestimate PWV when compared to methods restricted to the upslope-portion of the waveforms (p<0.05). In terms of regional PWV, a significant interaction was found between age and location (p<0.05). The age-related differences in regional PWV were greater in the proximal compared to distal descending aorta. CONCLUSION Care must be taken as different classes of methods for the estimation of travel-time produce different results. 4D flow MRI-based PWV estimation with piecewise linear regression modeling of travel-distance vs. travel time can discern age-related differences in regional PWV well in line with previously reported data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast semi-automated analysis of pulse wave velocity in the thoracic aorta using high temporal resolution 4D flow MRI

Background Pulse wave velocity (PWV) gives an indication of vessel stiffness, which can be used as a marker of age related changes in compliance, as well as to assess changes in vessel elasticity as a measure of atherosclerosis [1,2]. A recent meta-analysis showed PWV to be a robust predictor for cardiovascular events and all-cause mortality [3]. Recently, 4D flow MRI has been applied to assess...

متن کامل

Optimized Estimation of Global and Regional Aortic Pulse Wave Velocity

Introduction: Pulse wave velocity (PWV) as a measure of aortic stiffness is an important clinical marker for the presence of atherosclerosis [1,2]. For PWV estimation using Phase contrast (PC) MRI transit-time (TT) methods have been employed which estimate temporal differences in flow waveforms between two locations in the vessel with known distance [3]. However, precision was limited by the ac...

متن کامل

Global Pulse Wave Velocity in 87 Patients with Acute Ischemic Stroke and Aortic Atherosclerosis

Introduction: Increased pulse wave velocity (PWV) as a measure of aortic stiffness is an important marker for changes in aortic compliance and is an independent predictor of cardiovascular mortality and stroke. Reliable measurement of PWV is of particular interest for monitoring the progression or regression of vessel compliance during therapy [1-3]. Phase contrast (PC) MRI provides a noninvasi...

متن کامل

Quantification of aortic pulse wave velocity in preterm infants using 4D phase contrast MRI

Background 4D phase contrast (PC) MRI sequences providing full coverage of the aortic arch were acquired in neonates. Aortic pulse wave velocity (PWV) was then calculated from flow measurements taken at 5 to 8 locations along the arch and the aortic length between each location. Neonatal PWV values were compared with previously published adult values. Mechanical compliance within the healthy an...

متن کامل

Cardiac MRI: Clinical Challenges 4D Flow Imaging

Objectives • To review recent advances in phase contrast MRI methodology that allow for 4D Flow MRI acquisitions in clinically feasible scan times. • To review physiological markers that can be obtained with 4D Flow MRI, including vorticity, pressure maps, pulse wave velocity, .and wall shear stress. • To review potential limitations and potential sources of errors for velocity mapping and para...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance imaging

دوره 32 10  شماره 

صفحات  -

تاریخ انتشار 2014