Transient Beam Loading in the Als Harmonic Rf System*
نویسندگان
چکیده
We report on the commissioning of a higher harmonic radiofrequency system at the Advanced Light Source, designed to improve the beam lifetime. We have achieved an increase above a factor of two in our best results up to now. Transient beam loading of the harmonic cavities, due to the unequal fill patterns, creates the greatest limitations on lifetime improvement. We also describe several interesting effects on the operation of the longitudinal and transverse multibunch feedback systems.
منابع مشابه
Computed Transient Beam Loading Effects with Harmonic RF Systems
Harmonic cavities have been used in storage rings to lengthen bunches and increase beam lifetimes dominated by Touschek scattering. Transient beam loading in the harmonic cavities generated by asymmetries in the fill pattern can cause significant variation of the beam phase and bunch length along the bunch train when the longitudinal restoring force has been reduced, resulting in a significant ...
متن کاملThe Rf System for the 3 Harmonic Cavity of Als*
A higher harmonic cavity system is under construction in the ALS to extend beam lifetime. The implementation will be carried out in stages. The plan is to operate the system in the passive mode as a start and, depending on various factors, the plan may evolve into an active system eventually to attain the optimum beam lifetime at all beam current levels. The RF system must be designed according...
متن کاملStabilizing Effect of a Double-harmonic Rf System in the Cern Ps
Motivated by the discussions on scenarios for LHC upgrades, beam studies on the stability of flat bunches in a double-harmonic RF system have been conducted in the CERN Proton Synchrotron (PS). Injecting nearly nominal LHC beam intensity per cycle, 18 bunches are accelerated on harmonic h = 21 to 26 GeV with the 10 MHz RF system. On the flat-top, all bunches are then transformed to flat bunches...
متن کاملHigher Harmonics Beam Loading Compensation for a Broad Band Ma-loaded Rf Cavity
A broad band RF cavity loaded with magnetic alloy cores has been developed for the Japanese Hadron Facility synchrotrons. Its Q-value can be chosen at between 0.5 and 5. To reduce transient beam loading effects, a small Qvalue (< 3) is preferable to shorten the transient period. However, the circulating beam current of up to 7 A will induce a spurious voltage at the accelerating gap, which defo...
متن کاملLow-Level RF System Design for the Accelerator Test Facility (ATF) Damping Ring
The ATF damping ring [1] was built to demonstrate the production of low emittance, high current beams for future linear colliders. To attain high beam currents, multiple high current bunch trains are required. The low-level rf system should be designed to minimize both steady-state and transient beam loading effects in the accelerating cavities. In addition the design should be sufficiently fle...