Dialyzer Reuse and Outcomes of High Flux Dialysis

نویسندگان

  • Christos Argyropoulos
  • Maria-Eleni Roumelioti
  • Abdus Sattar
  • John A. Kellum
  • Lisa Weissfeld
  • Mark L. Unruh
چکیده

BACKGROUND The bulk of randomized trial evidence for the expanding use of High Flux (HF) hemodialysis worldwide comes from two randomized controlled trials, one of which (HEMODIALYSIS, HEMO) allowed, while the other (Membrane Outcomes Permeability, MPO) excluded, the reuse of membranes. It is not known whether dialyzer reuse has a differential impact on outcomes with HF vs low flyx (LF) dialyzers. METHODS Proportional Hazards Models and Joint Models for longitudinal measures and survival outcomes were used in HEMO to analyze the relationship between β2-microglobulin (β2M) concentration, flux, and reuse. Meta-analysis and regression techniques were used to synthesize the evidence for HF dialysis from HEMO and MPO. FINDINGS In HEMO, minimally reused (< 6 times) HF dialyzers were associated with a hazard ratio (HR) of 0.67 (95% confidence interval, 95%CI: 0.48-0.92, p = 0.015), 0.64 (95%CI: 0.44 - 0.95, p = 0.03), 0.61 (95%CI: 0.41 - 0.90, p = 0.012), 0.53 (95%CI: 0.28 - 1.02, p = 0.057) relative to minimally reused LF ones for all cause, cardiovascular, cardiac and infectious mortality respectively. These relationships reversed for extensively reused membranes (p for interaction between reuse and flux < 0.001, p = 0.005) for death from all cause and cardiovascular causes, while similar trends were noted for cardiac and infectious mortality (p of interaction between reuse and flux of 0.10 and 0.08 respectively). Reduction of β2M explained only 1/3 of the effect of minimally reused HF dialyzers on all cause mortality, while non-β2M related factors explained the apparent attenuation of the benefit with more extensively reused dialyzers. Meta-regression of HEMO and MPO estimated an adjusted HR of 0.63 (95% CI: 0.51-0.78) for non-reused HF dialyzers compared with non-reused LF membranes. CONCLUSIONS This secondary analysis and synthesis of two large hemodialysis trials supports the widespread use of HF dialyzers in clinical hemodialysis over the last decade. A mechanistic understanding of the effects of HF dialysis and the reuse process on dialyzers may suggest novel biomarkers for uremic toxicity and may accelerate membrane technology innovations that will improve patient outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhancement of Toxic Substances Clearance from Blood Equvalent Solution and Human Whole Blood through High Flux Dialyzer by 1 MHz Ultrasound

Background: Hemodialysis is a process of removing waste and excess fluid from blood when kidneys cannot function efficiently. It often involves diverting blood to the filter of the dialysis machin to be cleared of toxic substances. Fouling of pores in dialysis membrane caused by adhesion of plasma protein and other toxins will reduce the efficacy of the filtre.Objective: In This study, the infl...

متن کامل

Dialyzer reuse with peracetic acid does not impact patient mortality.

BACKGROUND AND OBJECTIVES Numerous studies have shown the overall benefits of dialysis filter reuse, including superior biocompatibility and decreased nonbiodegradable medical waste generation, without increased risk of mortality. A recent study reported that dialyzer reprocessing was associated with decreased patient survival; however, it did not control for sources of potential confounding. W...

متن کامل

Dialyzer reuse: justified cost saving for south Asian region.

In spite of controversies, dialyzer reuse has remained an integral part of hemodialysis because of lower cost, good overall safety record, and improved membrane biocompatibility. Reuse declined in developed countries from the beginning of this century because of mass production of hemodialyzers at favourable price with better biocompatible membrane. Abandoning dialyzer reuse became challenging ...

متن کامل

Effect of dialysis dose and membrane flux in maintenance hemodialysis.

BACKGROUND The effects of the dose of dialysis and the level of flux of the dialyzer membrane on mortality and morbidity among patients undergoing maintenance hemodialysis are uncertain. METHODS We undertook a randomized clinical trial in 1846 patients undergoing thrice-weekly dialysis, using a two-by-two factorial design to assign patients randomly to a standard or high dose of dialysis and ...

متن کامل

In vitro and in vivo evaluation of a new dialyzer.

BACKGROUND Recent dialyzer-related developments have concentrated upon the improvement of performance and biocompatibility. The focus of these developments was predominantly on the membrane itself. A newly developed high-flux dialyzer (FX60) with an advanced Fresenius Polysulfone) membrane (Helixone) overcomes this limitation and has several design-related advantages attributed to the redesign ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015