Kinematic calibration and pose measurement of a medical parallel manipulator by optical position sensors

نویسندگان

  • Shaoping Bai
  • Ming Yeong Teo
چکیده

In the applications of parallel manipulators, kinematic calibration is required to eliminate the errors resulting from the manufacturing and assembly of both base and tools. In this paper, a calibration method of base and tool transformation is developed by virtue of optical position sensors. An error model for calibration is constructed using differential geometry method. The pose error is obtained based on pose measurement results of OPTOTRAK 3020, a commercial 3D position measurement system. An iterative least squares procedure is used to identify the error parameters in the base and tool transformations. Simulation and experiment results are presented to demonstrate the effectiveness of the method for transformation matrices calibration. © 2003 Wiley Periodicals, Inc. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Calibration of the Constraining Linkage of a 4 Degrees of Freedom Parallel Manipulator

In this article, an experimental calibration of the constraining linkage of a wire-actuated parallel robot is discussed. The experimental test bed includes a prototyped 4 degrees of freedom wire-actuated parallel manipulator and an optical tracking system. The parallel manipulator employs hybrid actuation ofjoints and wires and includes a rigid branch to constrain the motion of its mobile platf...

متن کامل

Kinematic calibration of a parallel robot using coordinate measuring machine

In the applications of parallel robots, kinematic calibration is required to eliminate the errors resulting from the manufacturing and assembly. In this paper, a new method for calibrating a parallel robot is proposed. An error model for kinematic calibration is constructed using differential geometry method. All leg length information and pose error are obtained based on measurement results co...

متن کامل

Kinematic Calibration of a Cartesian Parallel Manipulator

Abstract: In this paper, a prototype Cartesian Parallel Manipulator (CPM) is demonstrated, in which a moving platform is connected to a fixed frame by three PRRR limbs. Due to the orthogonal arrangement of the three prismatic joints, it behaves like a conventional X-Y-Z Cartesian robot. However, because all the linear actuators are mounted at the fixed frame, the manipulator may be suitable for...

متن کامل

Kinematic Parameters Auto-Calibration of Redundant Planar 2-DOF Parallel Manipulator

Parallel manipulators have the advantage of high speed and high precision in the theory of mechanisms. This has opened up broad possibilities for the use of parallel manipulators in many fields. But in real applications, due to the inevitable manufacturing tolerances and assembling errors, the actual kinematic parameters of parallel manipulators are always unequal to the nominal values and cali...

متن کامل

Design and Kinematic Analysis of a 4-DOF Serial-Parallel Manipulator for a Driving Simulator

This paper presents the kinematic analysis and the development of a 4-degree-of-freedom serial-parallel mechanism for large commercial vehicle driving simulators. The degrees of freedom are selected according to the target maneuvers and the structure of human motion perception organs. Several kinematic properties of parallel part of the mechanism under study are investigated, including the inve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002