Fluorescence anisotropy measurements in solution: Methods and reference materials (IUPAC Technical Report)*

نویسندگان

  • Marcel Ameloot
  • Martin vandeVen
  • A. Ulises Acuña
  • Bernard Valeur
چکیده

After recalling the basic relations relevant to both steady-state and time-resolved fluorescence polarization, it is shown how the values of steady-state polarized intensities recorded experimentally usually need to be corrected for systematic effects and errors, caused by instrumentation and sample properties. A list of selected reference values of steady-state fluorescence anisotropy and polarization is given. Attention is also paid to analysis of time-resolved fluorescence anisotropy data obtained by pulse fluorometry or phase and modulation fluorometry techniques. Recommendations for checking the accuracy of measure ments are provided together with a list of selected time-resolved fluorescence anisotropy data as reported in the literature.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The characterization of macroporous solids: An overview of the methodology

This paper summarizes the principal aims, content and conclusions of a document recently submitted to IUPAC, as a Technical Report, by the IUPAC Working Group on ‘‘Liquid intrusion and alternative methods for the characterization of macroporous materials’’ and to be published in full in Pure and Applied Chemistry. The initial goal of the group was to list, examine and compare the methods presen...

متن کامل

Determination of hemolysis, osmotic fragility and fluorescence anisotropy on irradiated red blood cells as a function of kV of medical diagnostic X-rays

Background: People occasionally undergo medical diagnostic X-ray examinations and expose their red blood cells to radiation. Radiation that is generated from medical diagnostic X-ray machines is widely used in medical diagnoses. One of the important parameters is kilo-voltage (kV) that is applied across the X-ray tube in medical diagnostic X-ray machines. Kilo-voltage influences the radiation d...

متن کامل

Liquid intrusion and alternative methods for the characterization of macroporous materials (IUPAC Technical Report)*

This document deals with the characterization of porous materials having pore widths in the macropore range of 50 nm to 500 μm. In recent years, the development of advanced adsorbents and catalysts (e.g., monoliths having hierarchical pore networks) has brought about a renewed interest in macropore structures. Mercury intrusion–extrusion porosimetry is a well-established method, which is at pre...

متن کامل

Fixation alters fluorescence lifetime and anisotropy of cells expressing EYFP-tagged serotonin1A receptor.

Fluorescence microscopic approaches represent powerful techniques to monitor molecular interactions in the cellular milieu. Measurements of fluorescence lifetime and anisotropy enjoy considerable popularity in this context. These measurements are often performed on live as well as fixed cells. We report here that formaldehyde-induced cell fixation introduces heterogeneities in the fluorescence ...

متن کامل

Time-Resolved Fluorescence Anisotropy of Bicyclo[1.1.1]pentane/Tolane-Based Molecular Rods Included in Tris(o-phenylenedioxy)cyclotriphosphazene (TPP)

We examine the fluorescence anisotropy of rod-shaped guests held inside the channels of tris(o-phenylenedioxy)cyclotriphosphazene (TPP) host nanocrystals, characterized by powder X-ray diffraction and solid state NMR spectroscopy. We address two issues: (i) are light polarization measurements on an aqueous colloidal solution of TPP nanocrystals meaningful, or is depolarization by scattering exc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013