Refractive error sensing from wavefront slopes.
نویسنده
چکیده
The problem of measuring the objective refractive error with an aberrometer has shown to be more elusive than expected. Here, the formalism of differential geometry is applied to develop a theoretical framework of refractive error sensing. At each point of the pupil, the local refractive error is given by the wavefront curvature, which is a 2 × 2 symmetric matrix, whose elements are directly related to sphere, cylinder, and axis. Aberrometers usually measure the local gradient of the wavefront. Then refractive error sensing consists of differentiating the gradient, instead of integrating as in wavefront sensing. A statistical approach is proposed to pass from the local to the global (clinically meaningful) refractive error, in which the best correction is assumed to be the maximum likelihood estimation. In the practical implementation, this corresponds to the mode of the joint histogram of the 3 different elements of the curvature matrix. Results obtained both in computer simulations and with real data provide a close agreement and consistency with the main optical image quality metrics such as the Strehl ratio.
منابع مشابه
Maximum permissible torsional misalignment in aberration-sensing and wavefront-guided corneal ablation.
PURPOSE To determine the maximum permissible torsional misalignment in wavefront-guided refractive surgery. SETTING University of Zurich, Department of Ophthalmology, Zurich, Switzerland. METHODS The effect of torsionally misaligned ablations on the optical outcome was simulated using measured wavefront aberration patterns (2nd to 6th orders) in 130 normally aberrated eyes. The calculations...
متن کاملWave aberration of human eyes and new descriptors of image optical quality and visual performance.
The expansion of wavefront-sensing techniques redefined the meaning of refractive error in clinical ophthalmology. Clinical aberrometers provide detailed measurements of the eye's wavefront aberration. The distribution and contribution of each higher-order aberration to the overall wavefront aberration in the individual eye can now be accurately determined and predicted. Using corneal or ocular...
متن کاملRefractive Surgery Feature Story
SEPTEMBER 2010 CATARACT & REFRACTIVE SURGERY TODAY EUROPE 35 T he introduction of wavefront-sensing techniques to ophthalmology has redefined the clinical meaning of refractive error. Now, all imperfections in the components and materials within the eye that cause light rays to deviate from their desired path are referred to as optical aberrations. Lower-order aberrations (defocus and astigmati...
متن کاملHighlights of the 1st International Congress of Wavefront Sensing and Aberration-free Refractive Correction.
As we review the many new and evolving techniques for treating patients with customized ablation, it is obvious that there is a rapid evolution of technology and thought. Newly refined diagnostic technology, such as wavefront sensing, and more sophisticated spot laser delivery systems with eye tracking gives the refractive surgical team greater flexibility in tackling challenging optical abnorm...
متن کاملClinical outcomes of wavefront-guided laser in situ keratomileusis to treat moderate-to-high astigmatism
PURPOSE The purpose of this study was to evaluate the refractive and visual outcomes of wavefront-guided laser in situ keratomileusis (LASIK) in eyes with myopic astigmatism and cylindrical component ≥2.0 diopter (D). METHODS In this retrospective study, 611 eyes that underwent LASIK for simple or compound myopic astigmatism were analyzed. Preoperative refractive cylinder ranged from -2.00 D ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of vision
دوره 10 13 شماره
صفحات -
تاریخ انتشار 2010