Spectroscopic and Mechanical Properties of a New Generation of Bulk Fill Composites
نویسندگان
چکیده
Objectives: The aims of this study were to in vitro evaluate the degree of conversion and the microhardness properties of five bulk fill resin composites; in addition, the performance of two curing lamps, used for composites polymerization, was also analyzed. Materials and Methods: The following five resin-based bulk fill composites were tested: SureFil SDR®, Fill Up!™, Filtek™, SonicFill™, and SonicFill2™. Samples of 4 mm in thickness were prepared using Teflon molds filled in one increment and light-polymerized using two LED power units. Ten samples for each composite were cured using Elipar S10 and 10 using Demi Ultra. Additional samples of SonicFill2, (3 and 5 mm-thick) were also tested. The degree of conversion (DC) was determined by Raman spectroscopy, while the Vickers microhardness (VMH) was evaluated using a microhardness tester. The experimental evaluation was carried out on top and bottom sides, immediately after curing (t0), and, on bottom, after 24 h (t24). Two-ways analysis of variance was applied to evaluate DC and VMH-values. In all analyses, the level of significance was set at p < 0.05. Results: All bulk fill resin composites recorded satisfactory DCs on top and bottom sides. At t0, the top of SDR and SonicFill2 showed the highest DCs-values (85.56 ± 9.52 and 85.47 ± 1.90, respectively), when cured using Elipar S10; using Demi Ultra, SonicFill2 showed the highest DCs-values (90.53 ± 2.18). At t0, the highest DCs-values of bottom sides were recorded by SDR (84.64 ± 11.68), when cured using Elipar S10, and Filtek (81.52 ± 4.14), using Demi Ultra. On top sides, Demi Ultra lamp showed significant higher DCs compared to the Elipar S10 (p < 0.05). SonicFill2 reached suitable DCs also on bottom of 5 mm-thick samples. At t0, VMH-values ranged between 24.4 and 69.18 for Elipar S10, and between 26.5 and 67.3 for Demi Ultra. Using both lamps, the lowest VMH-values were shown by SDR, while the highest values by SonicFill2. At t24, all DC and VMH values significantly increased. Conclusions: Differences in DC and VMH among materials are suggested to be material and curing lamp dependent. Even at t0, the three high viscosity bulk composites showed higher VMH than the flowable or dual curing composites.
منابع مشابه
Comparing the Microleakage of Bulk-Fill (flowable, packable) Composite Restorations and Conventional Light-cured Composites
Introduction and aim: Bulk Fill composites have increased polymerization depth and their contraction stress, and cuspal deflection are reduced in comparison with conventional composites. Therefore, it is claimed that their microleakage is reduced. The aim of this study was to compare microleakage of (flowable and packable) Bulk Fill and conventional resin composites. Materials and Methods: Thi...
متن کاملA new approach for fabrication of bulk MMCs using Accumulative Channel-die Compression Bonding (ACCB)
A new severe plastic deformation (SPD) based technique entitled Accumulative channel-die compression bonding (ACCB) is proposed for the fabrication of high strength multi-layered Al/Cu composites for the first time. In order to primarily demonstrate the capabilities of ACCB in the fabrication of metal matrix composites (MMCs), AA 1050 and pure Cu strips were processed. The primary Al/Cu sandwic...
متن کاملPhysico-mechanical characteristics of commercially available bulk-fill composites.
OBJECTIVES Bulk-fill composites have emerged, arguably, as a new "class" of resin-based composites, which are claimed to enable restoration in thick layers, up to 4mm. The objective of this work was to compare, under optimal curing conditions, the physico-mechanical properties of most currently available bulk-fill composites to those of two conventional composite materials chosen as references,...
متن کاملMicroleakage of Bulk-Fill Composites at Two Different Time Points
Objectives: Microleakage is the main concern in composite restorations. This study aimed to compare the microleakage of two bulk-fill and one conventional composite at two different time points. Methods: Class II cavities were prepared in 60 premolar teeth and divided into six groups of 20. Groups 1 and 4 were incrementally filled with Grandio composite. Groups 2 and 5 were filled with X-tra...
متن کاملComparison of mechanical properties of a new fiber reinforced composite and bulk filling composites
OBJECTIVES The aim of this study was to evaluate the mechanical and physical properties of a newly developed fiber reinforced dental composite. MATERIALS AND METHODS Fiber reinforced composite EverX Posterior (EXP, GC EUROPE), and other commercially available bulk fill composites, including Filtek Bulk Fill (FB, 3M ESPE), SonicFill (SF, Kerr Corp.), SureFil (SDR, Dentsply), Venus Bulk Fill (V...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -
تاریخ انتشار 2016