The Simultaneous Determination of Six Flame Retardants in Water Samples Using SPE Pre-concentration and UHPLC-UV Method

نویسندگان

  • Bartosz Kowalski
  • Maciej Mazur
چکیده

Analytical method for the determination of six flame retardants (FRs) from two groups was proposed. These groups included the brominated flame retardants (BFRs) 3,3',5,5'-tetrabromobisphenol A (TBBPA), 1,2,5,6,9,10-hexabromocyclododecane (HBCD) and tetrabromophthalic anhydride (TBPA) and triester organophosphate flame retardants (OPFRs) tris(2,3-dibromopropyl) phosphate (TBPP), ethylhexyl diphenyl phosphate (EHDP) and triphenyl phosphate (TPhP). Reversed phase ultrahigh-performance liquid chromatography (UHPLC) with a UV detector, different chromatographic columns, different mobile phases and gradient elution programmes were used to obtain the best separations within the shortest possible time. Solid-phase extraction (SPE) was examined as a pre-concentration step from distilled water. The column with the highest recoveries (the Bond Elut ENV column gave recoveries over 70 % for all compounds) was then tested on 1-L blank surface water samples. The proposed analytical procedure was applied for the determination of FRs in surface water samples. The concentrations of FRs found in water samples ranged from 0.03 (TPhP) to 3.10 μg L-1 (HBCD). Method detection limits (MDLs) ranged from 0.008 to 0.518 μg L-1, and method quantification limits (MQLs) ranged from 0.023 to 1.555 μg L-1 for all compounds.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

UPLC-MS/MS Determination of Organophosphorus Flame Retardants and Ultraviolet Absorbers in River Water and STP Effluent Samples

A sensitive, selective and rapid method for the analysis of organophosphorus flame retardants (OPFRs) and ultraviolet absorbers (UVAs) in river water and STP effluent samples by solid-phase extraction (SPE) with ultra-performance liquid chromatography tandem mass spectrometry (UPLCMS/MS) was developed. It allows the determination of 8 OPFRs and 6 UVAs. A single SPE consisting on the loading 200...

متن کامل

Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples

Few methods are available for comprehensive organophosphate flame retardants (PFRs) detection in water and wastewater. Gas chromatography has been employed previously, but this approach is less selective, not amenable for use with deuterated standards and can suffer unfavorable fragmentation. Ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-QqQ-MS/MS) has become the mos...

متن کامل

A Rapid UHPLC Method for the Simultaneous Determination of Drugs from Different Therapeutic Groups in Surface Water and Wastewater

A SPE-UHPLC-UV method for the determination of 13 pharmaceuticals from different therapeutic groups in surface water and wastewater samples was proposed. The following three solid-phase-extraction (SPE) columns with polymeric sorbents were used as a pre-concentration step: the Oasis HLB (average recoveries 93.8 %), the Nexus (84.0 %) and the Bond Elut ENV (88.3 %). A reverse-phase UHPLC with a ...

متن کامل

Optimization and Simultaneous Determination of Alkyl Phenol Ethoxylates and Brominated Flame Retardants in Water after SPE and Heptafluorobutyric Anhydride Derivatization followed by GC/MS

A gas chromatography-mass spectrometry (GC-MS) method was investigated for the simultaneous analysis of two types of endocrine disrupting compounds (EDCs), i.e., alkylphenol ethoxylates and brominated flame retardants (BFRs), by extraction and derivatization followed by GC-MS. Different solid phase extraction (SPE) cartridges (Cleanert PestiCarb, C18, Cleanert-SAX and Florosil), solvents (tolue...

متن کامل

Application of Microfunnel Magnetic Stirring Assisted Liquid-Liquid Micro-extraction Method for Pre-concentration and Determination of Silver Ion in Water Samples

In this research, a highly sensitive, selective, rapid and simple micro-funnel magnetic stirringassisted liquid–liquid microextraction (MF-MSA-LLME) method combined with flame atomic absorption spectrometry (FAAS) was introduced for the preconcentration, extraction, and measurement of trace amounts of silver ion. In this method 1-(2–Pyridylazo)-2-naphthol (PAN) and 1-octanol were used as chelat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 225  شماره 

صفحات  -

تاریخ انتشار 2014