A Comparative Study of Intraocular Pressure Measurement Using Tonopen and Goldmann Applanation Tonometer

نویسندگان

  • Rajesh R Nayak
  • Pooja Kandula
  • Bhavini Johri
  • Shobha G Pai
  • Sumana J Kamath
چکیده

Background: Glaucoma is the world's leading cause of preventable irreversible blindness. The most important risk factor of glaucoma is increase in the intraocular pressure.Hence, timely screening by accurate IOP measurements is of utmost importance. In recent years, Tonopen has emerged as an alternative to Goldmann applanation tonometer which is the ‘gold standard’ for IOP measurement because of its various advantages. Since its reliability has not yet been confirmed, this study aims to assess the accuracy of the Tonopen in measuring the IOP as compared to the Goldmann applanation tonometer. Objective: To determine whether Tonopen is accurate and reliable in measuring the intraocular pressure as compared to Goldmann applanation tonometer. Methodology: In this prospective cross-sectional study, 113 patients above 40 years coming for routine eye check-up and who were diagnosed earlier as glaucoma patients their IOP was measured. The Tonopen was used first followed by the Goldmann applanation tonometer. Collected data was analyzed using SPSS version 17.0. The results were expressed in terms of sensitivity, specificity, positive and negative predictive value and accuracy rate. Institutional Ethics Committee clearance was obtained prior to commencement of study. Results: For the right eye, the sensitivity of the Tonopen in detecting glaucoma was 60% and the specificity was 94.44%. The positive predictive value and the negative predictive value were 33.33%and 98.08% respectively. Percentage of false-negatives obtained were 40% and percentage of false-positives obtained were 5.55%. Accuracy rate of the Tonopen was 92.92%. For the left eye, sensitivity was 75% and specificity was 96.33%. The Positive predictive value and negative predictive value were42.86% and 99.06% respectively. Percentage of false-negatives obtained were 25% and percentage of false-positives were 3.67%. Accuracy rate of the Tonopen was 95.57%. Area under the Receiver Operating Characteristic curve was 0.887 with a standard error of 0.085 in case of the right eye. For the left eye, the area under the curve was 0.972 with a standard error of 0.027. Conclusion: According to this study, the Tonopen is an accurate and reliable indicator of Intraocular pressure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty

PURPOSE Post-Descemet stripping endothelial keratoplasty (DSEK) patients are prone for intraocular pressure (IOP) elevations and glaucoma. Corneal characteristics influence various IOP measuring devices in various ways. The aim of this study was to evaluate the agreement between four different IOP measuring devices: Goldmann applanation tonometer (GAT), I-care pro, Tonopen XL, and Schiotz tonom...

متن کامل

A Comparative Study of Rebound Tonometry With Tonopen and Goldmann Applanation Tonometry Following Vitreoretinal Surgery.

PURPOSE To investigate agreement in intraocular pressure (IOP) measurements among Icare rebound tonometry, Tonopen tonometry, and Goldmann applanation tonometry following vitreoretinal surgery. DESIGN Reliability analysis of tonometers. METHODS Fifty-eyes of 50 adults undergoing vitreoretinal surgery were enrolled. IOP was measured on first postoperative day using Icare (Tiolat, Helsinki, F...

متن کامل

Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer.

AIMS To investigate the effect of central corneal thickness and corneal curvature on intraocular pressure measurements using the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer, and to assess the agreement between the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer in intraocular pressure measurement. METHODS 479 subjects underwent int...

متن کامل

Two-position measurement of intraocular pressure by PT100 noncontact tonometry in comparison with Goldmann tonometry

BACKGROUND The purpose of this study was to evaluate the precision of intraocular pressure measurements obtained by PT100 noncontact tonometry in a handheld and slit lamp-mounted position in comparison with that of Goldmann applanation tonometry in healthy young adults. METHODS Sixty eyes from 60 subjects (30 men and 30 women) aged 22 ± 1 (range 20-24) years participated in this study. Tripli...

متن کامل

Intraocular pressure measurement: Goldmann Applanation Tonometer vs non contact airpuff tonometer.

BACKGROUND An accurate assessment of Intraocular pressure (IOP) is vital in establishing diagnosis of Glaucoma and decision making regarding various treatment modalities available. The purpose of this study is to compare Goldmann Applanation Tonometer (GAT) with Air puff tonometer. METHODS Cross-sectional comparative study conducted. 73 eyes from 73 patients were included in this study and in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017