LC–UV/MS quality analytics of paediatric artemether formulations
نویسندگان
چکیده
A highly selective and stability-indicating HPLC-method, combined with appropriate sample preparation steps, is developed for β-artemether assay and profiling of related impurities, including possible degradants, in a complex powder for oral suspension. Following HPLC conditions allowed the required selectivity: a Prevail organic acid (OA) column (250 mm×4.6 mm, 5 μm), flow rate set at 1.5 mL/min combined with a linear gradient (where A=25 mM phosphate buffer (pH 2.5), and B=acetonitrile) from 30% to 75% B in a runtime of 60 min. Quantitative UV-detection was performed at 210 nm. Acetonitrile was applied as extraction solvent for sample preparation. Using acetonitrile-water mixtures as extraction solvent, a compartmental behaviour by a non-solving excipient-bound fraction and an artemether-solubilising free fraction of solvent was demonstrated, making a mobile phase based extraction not a good choice. Method validation showed that the developed HPLC-method is considered to be suitable for its intended regulatory stability-quality characterisation of β-artemether paediatric formulations. Furthermore, LC-MS on references as well as on stability samples was performed allowing identity confirmation of the β-artemether related impurities. MS-fragmentation scheme of β-artemether and its related substances is proposed, explaining the m/z values of the in-source fragments obtained.
منابع مشابه
Development of reliable quality control methods for TCM preparations using rapid resolution LC with UV and MS detection
This Application Note describes the development of reliable quality control methods for analysis of individual traditional Chinese medicines (TCMs) and TCM formulations using rapid resolution liquid chromatography with UV-visible and quadrupole mass spectrometry detection. The chromatograms obtained with UV and MS detection for different individual TCMs are compared and the combination of UV an...
متن کاملBook Review | New Books May 2004 Toxicogenomics
Background: Artemisinin-derivative formulations are now widely used to treat falciparum malaria. However, the dry powder suspensions developed for children are few and/or are of poor quality. In addition to the active compound, the presence of a suitable preservative in these medicines is essential. In this study, an evaluation of the preservative content and efficacy in some dry suspensions av...
متن کاملA Quick and Sensitive Liquid Chromatography-Tandem Mass Spectrometry (LC-MS) Method for the Evaluation of Two Formulations of Amlodipine and Atorvastatin in Healthy Male Volunteers
An open-label, single-dose, randomized, 2-way crossover study was conducted in fasted healthy Iranian male volunteers. Eligible participants randomly assigned in a 1:1 ratio to be given one tablet of the test or reference formulation, followed by a 2-week washout period and administration of the exchange formulation. A quick and susceptible Liquid Chromatography–tandem Mass Spectro...
متن کاملComparative Study of Captopril Derivatization Reaction by LC-UV, LC-MS and CE-UV Methods
The LC-UV, LC-MS and CE-UV study of chemical reaction between captopril and p-bromophenacyl bromide as derivatizing reagent is reported. During transformation of captopril, its thiol group is involved and the reaction is irreversible. Neutral or alkaline environments favor derivatization. The yield of reaction increases linear with the concentration of the reagent, while changes in temperature ...
متن کاملA simple and rapid reversed-phase liquid chromatography (LC) method with photodiode array (PDA) and electrospray ionization
method with photodiode array (PDA) and electrospray ionization (ESI)–mass spectrometry (MS) as detectors was developed and validated to separate, identify, and quantitate the related substances of Doxazosin mesylate (DXZN) for monitoring the reactions involved during process development. The highperformance liquid chromatography profiles of related-substances of DXZN are used as fingerprints to...
متن کامل