PURPOSE: Patient-specific heart and valve models have shown promise as training and planning tools for heart surgery, but physically realistic valve models remain elusive. Available proprietary, simulation-focused heart valve models are generic adult mitral valves and do not allow for patient-specific modeling as may be needed for rare diseases such as congenitally abnormal valves. We propose creating silicone valve models from a 3D-printed plastic mold as a solution that can be adapted to any individual patient and heart valve at a fraction of the cost of direct 3D-printing using soft materials. METHODS: Leaflets of a pediatric mitral valve, a tricuspid valve in a patient with hypoplastic left heart syndrome, and a complete atrioventricular canal valve were segmented from ultrasound images. A custom software was developed to automatically generate molds for each valve based on the segmentation. These molds were 3D-printed and used to make silicone valve models. The models were designed with cylindrical rims of different sizes surrounding the leaflets, to show the outline of the valve and add rigidity. Pediatric cardiac surgeons practiced suturing on the models and evaluated them for use as surgical planning and training tools. RESULTS: Five out of six surgeons reported that the valve models would be very useful as training tools for cardiac surgery. In this first iteration of valve models, leaflets were felt to be unrealistically thick or stiff compared to real pediatric leaflets. A thin tube rim was preferred for valve flexibility. CONCLUSION: The valve models were well received and considered to be valuable and accessible tools for heart valve surgery training. Further improvements will be made based on surgeons’ feedback.
منابع مشابه
Image Segmentation and Modeling of the Pediatric Tricuspid Valve in Hypoplastic Left Heart Syndrome
Hypoplastic left heart syndrome (HLHS) is a single-ventricle congen‐ ital heart disease that is fatal if left unpalliated. In HLHS patients, the tricuspid valve is the only functioning atrioventricular valve, and its competence is there‐ fore critical. This work demonstrates the first automated strategy for segmenta‐ tion, modeling, and morphometry of the tricuspid valve in transthoracic 3D ech...
متن کاملPatient-specific CFD simulation of intraventricular haemodynamics based on 3D ultrasound imaging
BACKGROUND The goal of this paper is to present a computational fluid dynamic (CFD) model with moving boundaries to study the intraventricular flows in a patient-specific framework. Starting from the segmentation of real-time transesophageal echocardiographic images, a CFD model including the complete left ventricle and the moving 3D mitral valve was realized. Their motion, known as a function ...
متن کاملThree-dimensional-printed cardiac prototypes aid surgical decision-making and preoperative planning in selected cases of complex congenital heart diseases: Early experience and proof of concept in a resource-limited environment
INTRODUCTION Three-dimensional. (3D) printing is an innovative manufacturing process that allows computer-assisted conversion of 3D imaging data into physical "printouts" Healthcare applications are currently in evolution. OBJECTIVE The objective of this study was to explore the feasibility and impact of using patient-specific 3D-printed cardiac prototypes derived from high-resolution medical...
متن کاملIntroduction and Use of an Education-notification Application for Patients Undergoing Heart Valve Replacement
Proper education and notification of patients undergoing heart valve replacement is of paramount importance. The past decade has witnessed a growing interest in the use of modern, advanced technologies in medicine and patient education. This study aimed to introduce an education-notification application for patients undergoing heart valve replacement. Research was carried out in two phases of s...
متن کامل1302 . P 6 . 51 . Using Real - Time Three - Dimensional Ultrasound To Characterize Mitral Valve Motion
Real-time 3D ultrasound has become a promising new tool for diagnostic and interventional cardiac procedures. In particular, full volume analysis of cardiac structures is now possible because of ultrasound's high tissue/blood contrast and a temporal resolution capable of capturing fast-moving cardiac structures. The temporal resolution of three-dimensional ultrasound is particularly attractive ...