The influence of instrument configuration on tissue handling force in laparoscopy.
نویسندگان
چکیده
In single-access surgery, instruments enter the abdominal cavity through only 1 incision, the position of the instruments relative to each other is different compared with that in conventional laparoscopy. Changes in instrument configuration may increase task complexity and therefore affect tissue handling skills. The aim of this study is to determine if a relation exists between instrument configuration and tissue interaction force. A study was performed to investigate the differences in manipulation force between a single-port (SP) and 2-port (TP) instrument configuration in a standard box trainer. A force platform was placed under a tissue manipulation task in a box trainer and used to measure the pulling forces and trial time. A total of 28 medical students with no previous experience in laparoscopic surgery were divided into 2 equal groups. Group 1 trained the task 6 times with the TP configuration and subsequently performed 6 trials with the SP configuration. Group 2 used the configurations in the opposite order. For both groups, the learning curves of the maximum force and task time were compared. Time and maximum pulling forces were significantly different between the 2 instrument configurations. In both groups, the participants used significantly more force in the SP configuration than in the TP configuration. The force data indicate that the increased complexity in instrument handling with straight instruments in a SP configuration increases the tissue manipulation force. Furthermore, the tissue handling skills of novices who mastered the task with the TP configuration decreased after switching to the SP configuration.
منابع مشابه
مقایسه نیروهای وارد بر کمر در وظایف جابجایی دستی بیمار
Background: Patient Manual handling is one of the major risk factors in musculoskeletal disorders among healthcare workers (HCWs). Therefore, the purpose of this study was to estimate the mechanical force on the low back of the staff responsible for patient manual handling and to exam in the effect of patient manual handling by two people on the level forces exerted on HCWs ҆ low back. meth...
متن کاملElectromagnetic field analysis of novel low cogging force, linear switched reluctance motor, based on 2-D finite element method
This paper deals with electromagnetic design and 2-D (two-dimensional) magnetic field analysis of novel low force ripple linear switched reluctance (LSR) motor. The configuration that has been presented here has a higher number of rotor poles than stator poles, and the purpose of this configuration is to improve the force ripple, which is the weak point of LSRMs. In order to illustrate the ...
متن کاملAssessing the role of enema in improving outcomes and complications of benign gynecological laparoscopy: a randomized clinical trial
Background: mechanical bowel preparation (MBP) is a common practice before laparoscopic gynecologic surgeries but the role and efficacy of preparation have been questioned. this study assesses visualization and bowel handling in a group of patients who receive MBP and the control group and thereafter; compares the results. Methods: We designed and conducted this randomized, single-blinded and ...
متن کاملReliability Measures Improvement and Sensitivity Analysis of a Coal Handling Unit for Thermal Power Plant
The present paper investigates the reliability and sensitivity analysis of a coal handling unit of a thermal power plant using a probabilistic approach. Coal handling unit is the main block of a thermal power plant and it is necessary for a good function of a power plant that its power supply, which is dealt in coal handling unit, must function continuously without any obstacle. The configurati...
متن کاملBack Compressive Force (BCF) assessment using UTAH method in manual handling tasks among workers of a chemical manufacturing company
Background: Job back pain is of the most common occupational injuries in the world that affects people's physical and mental health. The purpose of this study was to assess back compressive force (BCF) in manual handling tasks among workers of a chemical manufacturing company using the UTAH method. Materials and Methods: This descriptive study was carried out on a group of 35 workers doing man...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Surgical innovation
دوره 20 3 شماره
صفحات -
تاریخ انتشار 2013