Left bundle branch block after sutureless, transcatheter, and stented biological aortic valve replacement for aortic stenosis.

نویسندگان

  • Madelien V Regeer
  • Lisanne R Merkestein
  • Arend de Weger
  • Vasileios Kamperidis
  • Frank van der Kley
  • Philippe J van Rosendael
  • Nina Ajmone Marsan
  • Robert J M Klautz
  • Martin J Schalij
  • Jeroen J Bax
  • Victoria Delgado
چکیده

AIMS Conventional aortic valve replacement (AVR), sutureless AVR (su-AVR) and transcatheter aortic valve implantation (TAVI) for severe aortic stenosis (AS) are associated with conduction abnormalities. The aim of the present study was to assess the incidence of left bundle branch block (LBBB) after su-AVR and TAVI, in comparison to conventional AVR. METHODS AND RESULTS A total of 501 patients (mean age 74±8 years, 53% male) without preoperative cardiac conduction disturbances who underwent AVR or TAVI were included in the study. Su-AVR patients and TAVI patients had a higher incidence of new-onset LBBB at hospital discharge (23% and 16%, respectively) compared to patients treated with conventional AVR (4%; p<0.001). On multivariate logistic regression analyses, the type of AVR was independently associated with complete LBBB, after correcting for age, preoperative QRS duration and heart rate (su-AVR and TAVI relative to the reference category conventional AVR: odds ratio [OR] 8.5, 95% confidence interval [CI]: 3.7-19.5; p<0.001, and OR 5.8, 95% CI: 2.4-14.1; p<0.001, respectively). CONCLUSIONS Su-AVR and TAVI were associated with higher risk of developing postoperative LBBB compared to conventional AVR, after adjusting for age, preoperative heart rate and QRS duration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Case of Transient Advanced Atrioventricular Block after Aortic Valve Replacement, Report of a Case

Approximately 3% 11.8% of cases require permanent pacemaker implantation due to atrioventricular block (AVB) after aortic valve replacement (AVR), and determination of conduction disturbances such as left or right bundle branch block by preoperative electrocardiography is correlated with high risk postoperative permanent pacemaker implantation. Intraoperative risk factors include severe calcifi...

متن کامل

Low permanent pacemaker rates following Lotus device implantation for transcatheter aortic valve replacement due to modified implantation protocol.

BACKGROUND Conduction disturbances requiring permanent pacemaker implantation following transcatheter aortic valve replacement (TAVR) are a common problem. Pacemaker implantation rates after TAVR appear to be higher compared to conventional aortic valve replacement. The aim of this study was to analyze whether a high annulus implantation conveys the benefit of a decreased rate of permanent pace...

متن کامل

Arrhythmia burden in elderly patients with severe aortic stenosis as determined by continuous electrocardiographic recording: toward a better understanding of arrhythmic events after transcatheter aortic valve replacement.

BACKGROUND This study sought to evaluate the prevalence of previously undiagnosed arrhythmias in candidates for transcatheter aortic valve replacement (TAVR) and to determine the impact on therapy changes and arrhythmic events after the procedure. METHODS AND RESULTS A total of 435 candidates for TAVR underwent 24-hour continuous ECG monitoring the day before the procedure. Newly diagnosed ar...

متن کامل

Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis.

AIMS New-onset left bundle branch block (LBBB) and complete atrioventricular block (AV3B) frequently occur following transcatheter aortic valve implantation (TAVI). We sought to determine the timing and potential mechanisms of new conduction abnormalities (CAs) during TAVI, using the Medtronic CoreValve System (MCS). METHODS AND RESULTS Sixty-five consecutive patients underwent TAVI with cont...

متن کامل

Bundle branch reentrant ventricular tachycardia after transcatheter aortic valve replacement

Introduction Bundle branch reentrant ventricular tachycardia (BBR-VT) is a well-described entity that accounts for 6% of inducible sustained monomorphic VT during electrophysiology studies. BBR-VT is a macroreentrant VT involving the HisPurkinje system and usually requires some form of conduction delay in the His-Purkinje axis. BBR-VT is commonly seen in patients with nonischemic dilated cardio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology

دوره 12 13  شماره 

صفحات  -

تاریخ انتشار 2017