Common-Path Fourier-Domain Optical Coherence Tomography using Surface Tracking Algorithm

نویسندگان

  • C. G. Song
  • K. S. Kim
  • M. H. Kim
  • S. H. Ryu
  • J. H. Seo
چکیده

Conventional optical coherence tomography (OCT) systems generally have a limited imaging range within a depth of only 1-2 mm and suffers from unwanted noise such as speckle, ghost or mirror noise. To overcome these limitations, we developed a motorized-stage-based OCT system with an extended imaging range, using a common-path Fourier-domain optical coherence tomography (CP-FD-OCT) configuration. Using this OCT systems, OCT image was obtained from an onion, and their subsurface structure were observed. The result showed that the OCT images obtained using our motorized-stage-based system had a significantly extended imaging range due to its real-time accurate depth tracking. Consequently, the devised CP-FD-OCT systems and algorithms have good potential for the further development of endoscopic OCT for microsurgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

اندازه‌گیری همزمان ضریب شکست و ضخامت فیزیکی دستگاه‌های چندلایه‌ای با استفاده از نتایج مقطع‌نگاری همدوسی اپتیکی در فضای فوریه

In fourier domain optical coherence tomography, we can measure the optical thickness ( refractive index n times thickness d), to obtain the retinal layers in order to diagnose many disorders. In this work, we introduce a new method for measurement of refractive index and physical thickness of multiple layers simultaneously by Fourier domain optical coherence tomography, without additional infor...

متن کامل

Tissue surface as the reference arm in Fourier domain optical coherence tomography.

We present a simple method applicable to common-path Fourier domain optical coherence tomography (OCT) in which the tissue surface is used as the reference arm. We propose using aluminium hydroxide powder as a potential tissue surface diffuser to allow wider application of this method. This technique allows one to avoid placing a reference arm reflective element, such as glass plate, on tissue,...

متن کامل

Quantitative phase imaging with spectral-domain optical coherence phase microscopy

Spectral domain optical coherence phase microscopy provides high resolution quantitative phase measurement. Using a common path Fourier domain optical coherence tomography system, this technique is capable of excellent phase stability of less than 1 milliradian and high imaging speed of up to several hundred KHz Aline rate. The limitation of 2π ambiguity restriction can be overcome by the use o...

متن کامل

Synchronous self-elimination of autocorrelation interference in Fourier-domain optical coherence tomography.

We have developed a new algorithm and configuration for self-eliminating the autocorrelation of the object wave in Fourier-domain optical coherence tomography. A self-interferogram of the object wave is acquired synchronously with the standard interferogram of the recombined object and reference waves. The former is then subtracted from the latter after Fourier transformation. The algorithm is ...

متن کامل

Motion-compensated hand-held common-path Fourier-domain optical coherence tomography probe for image-guided intervention

A motion-compensated, hand-held, common-path, Fourier-domain optical coherence tomography imaging probe has been developed for image-guided intervention during microsurgery. A hand-held prototype instrument was achieved by integrating an imaging fiber probe inside a stainless steel needle and attached to the ceramic shaft of a piezoelectric motor housed in an aluminum handle. The fiber probe ob...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011