Local Rigid and Volume preserving deformable registration method with applications to liver MR data
نویسندگان
چکیده
1) T. Rohlfing, et. al., IEEE TMI, vol. 22, no. 6, June 2003. 2) E. Haber, et. al., Lecture Notes in Comp. Sci., pg. 561-572, 2005. 3) M. Staring, et. al., SPIE MI, vol. 6144, 2006. 4) X. Li, et. al., Magnetic Resonance Imaging, 2009. 5) K. A. Saddi, et. al., SPIE MI, vol. 6512, 2007. 6) D. Ruan, et. al., SPIE MI, 2006. 7) C. Chefd’Hotel, et. al. ISBI. July:753-756 2002 Figure 1: Flowchart of the proposed method. The deformation field is modified before application, making it applicable to almost all registration techniques.
منابع مشابه
Evaluation of deformable image registration in HDR gynecological brachytherapy
Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...
متن کاملA Novel Subsampling Method for 3D Multimodality Medical Image Registration Based on Mutual Information
Mutual information (MI) is a widely used similarity metric for multimodality image registration. However, it involves an extremely high computational time especially when it is applied to volume images. Moreover, its robustness is affected by existence of local maxima. The multi-resolution pyramid approaches have been proposed to speed up the registration process and increase the accuracy of th...
متن کاملThe Accuracy of ADC Measurements in Liver Is Improved by a Tailored and Computationally Efficient Local-Rigid Registration Algorithm
This study describes post-processing methodologies to reduce the effects of physiological motion in measurements of apparent diffusion coefficient (ADC) in the liver. The aims of the study are to improve the accuracy of ADC measurements in liver disease to support quantitative clinical characterisation and reduce the number of patients required for sequential studies of disease progression and ...
متن کاملCompensation of brain shift during surgery using non-rigid registration of MR and ultrasound images
Background: Surgery and accurate removal of the brain tumor in the operating room and after opening the scalp is one of the major challenges for neurosurgeons due to the removal of skull pressure and displacement and deformation of the brain tissue. This displacement of the brain changes the location of the tumor relative to the MR image taken preoperatively. Methods: This study, which is done...
متن کاملAutomatic Rigid and Deformable Medical Image Registration
Advanced imaging techniques have been widely used to study the anatomical structure and functional metabolism in medical and clinical applications. Images are acquired from a variety of scanners (CT/MR/PET/SPECT/Ultrasound), which provide physicians with complementary information to diagnose and detect specific regions of a patient. However, due to the different modalities and imaging orientati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009