The Influence of Tube Potential on Periodontal Bone Level Measurements and Subjective Image Quality Using a Digital Photostimulable Storage Phosphor Sensor
نویسندگان
چکیده
OBJECTIVES The purpose of the present study was to determine the measurement accuracy and subjective image quality for periodontal disease diagnosis when using two X-ray tube voltages with a digital photostimulable storage phosphor sensor. MATERIAL AND METHODS A digital photostimulable storage phosphor (PSP) sensor (Vistascan) and a multipulse X-ray generator (Prostyle Intra) with two tube voltages were used in this study. The front, premolar and molar region of two adult human cadaver skulls jaws were imaged using the X-ray tube at 63 kV and 70 kV, both at 8 mA and decreasing exposure times (160 ms, 120 ms and 80 ms). A standardized exposure protocol containing waxed occlusal keys and an aiming device ensured proper and reproducible beam alignment. Three observers assessed the digital radiographs for 31 selected periodontal bone loss sites. Radiographic measurements were compared to physical measurements (Standard). Subjective ratings of lamina dura, crater defect and furcation involvement visibility, contrast perception and bone quality were also performed. RESULTS Multiple regression equation of the variables kV and exposure time demonstrated no significant difference for the periodontal bone level measurements (P > 0.05). In 90.3% and 96.7% of the measurements for 70 kV and 63 kV respectively, deviation was within 1 mm. The subjective ratings produced similar findings in terms of image quality for both tube voltages and the three exposure times. CONCLUSIONS The results of the present study revealed that tube voltages of 63 kV and 70 kV provided similar accuracy and image quality for periodontal disease diagnosis.
منابع مشابه
Quality comparison of direct digital panoramic radiography and computed radiography panoramic
BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...
متن کاملتوموگرافی خطی با فیلم و Photostimulable Phosphor Plate در طرح درمان ایمپلنت در مندیبل
Background and Aims: Radiographic examination prior to implant placement is often complemented with tomography for location of vital anatomic structures and evaluation of bone volume. The aim of this study was to evaluate the accuracy of Photostimulable Phosphor Plate system with that of conventional film-screen in mandibular pre-implant linear tomography Materials and Methods: In this test eva...
متن کاملComparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects
Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects. Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...
متن کاملEstimation of Remnant Dentin Thickness under Proximal Caries Using Digital Bitewing Radiography: An In-Vitro Study
Objectives: In restorative dentistry, it is essential to estimate the amount of remnant tooth structure after caries removal to make the best treatment plan. The present study was aimed to determine whether there is a correlation between the real thickness of remnant dentin under carious lesion and the radiographical measurement from photostimulable phosphor plates (PSPs). Methods: a whole numb...
متن کاملمقایسه سنسورهای دیجیتالی Charge-Coupled Device با Photostimulable Phosphor Storage Plate در تشخیص شکستگی عمودی ریشه در دندانهای اندو شده (مطالعه آزمایشگاهی)
Objective: Vertical root fracture (VRF) is among the most common causes of endodontic treatment failures. This study aims to compare charge-coupled devices (CCD) and photostimulable phosphor plates (PSP) for detection of vertical root fractures in endodontically treated teeth. Methods: In this diagnostic in vitro study, 40 maxillary anterior teeth were selected and after preparation and roo...
متن کامل