Velocimetria laser de escoamento permanente através de duas próteses cardíacas de duplo folheto

نویسندگان

  • Ovandir Bazan
  • Jayme Pinto Ortiz
  • Francisco Ubaldo Vieira Junior
  • Reinaldo Wilson Vieira
  • Nilson Antunes
  • Fabio Bittencourt
چکیده

Introduction: In vitro hydrodynamic characterization of prosthetic heart valves provides important information regarding their operation, especially if performed by noninvasive techniques of anemometry. Once velocity profiles for each valve are provided, it is possible to compare them in terms of hydrodynamic performance. In this first experimental study using laser doppler anemometry with mechanical valves, the simulations were performed at a steady flow workbench. Objective: To compare unidimensional velocity profiles at the central plane of two bi-leaflet aortic prosthesis from St. Jude (AGN 21 – 751 and 21 AJ – 501 models) exposed to a steady flow regime, on four distinct sections, three downstream and one upstream. Methods: To provide similar conditions for the flow through each prosthesis by a steady flow workbench (water, flow rate of 17L/min.) and, for the same sections and sweeps, to obtain the velocity profiles of each heart valve by unidimensional measurements. Results: It was found that higher velocities correspond to the prosthesis with smaller inner diameter and instabilities of flow are larger as the section of interest is closer to the valve. Regions of recirculation, stagnation of flow, low pressure, and flow peak velocities were also found. Conclusions: Considering the hydrodynamic aspect and for every section measured, it could be concluded that the prosthesis model AGN 21 751 (RegentTM) is superior to the 21 AJ – 501 model (Master Series). Based on the results, future studies can choose to focus on specific regions of the these valves. Descriptors: Heart valve prosthesis. Blood flow velocity. Laser-Doppler flowmetry. Resumo Introdução: A caracterização hidrodinâmica in vitro de próteses de válvulas cardíacas fornece informações importantes quanto ao seu funcionamento, sobretudo se realizada por meio de métodos não-invasivos de anemometria. Uma vez obtidos os perfis de velocidade para cada válvula, é possível compará-las quanto ao seu desempenho hidrodinâmico. Neste primeiro estudo experimental de anemometria laser com válvulas mecânicas,

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Atmospheric Corrosion of Galvanized Steel and Precipitation Runoff from Zinc in a Marine Environment

Este estudo focaliza o comportamento do aço galvanizado em um ambiente marinho corrosivo e no processo de escoamento superficial para o mesmo material que ocorrem em Valparaíso, Chile. O potencial de corrosão e a taxa de corrosão avaliados através de perda de massa foram utilizados para determinar os danos da corrosão para o aço galvanizado. As composições dos produtos de corrosão foram determi...

متن کامل

Analysis of the Photo Conversion of Asphaltenes Using Laser Desorption Ionization Mass Spectrometry: Fragmentation, Ring Fusion, and Fullerene Formation

The conversion or photo conversion of asphaltenes to polycyclic aromatic hydrocarbons (PAH’s) promoted by a laser source is analyzed using both experimental and theoretical methods. We propose that during measurements performed at an intermediate laser power, fragmentation to afford PAH’s and ring fusion to yield fused PAH’s (FPAH’s) may occur either within molecular clusters (resin case) or wi...

متن کامل

Pharmacokinetic Profile of Liposome-Encapsulated Ropivacaine after Maxillary Infiltration Anaesthesia

O objetivo do presente estudo foi determinar os parâmetros farmacocinéticos da ropivacaína encapsulada em lipossomas após anestesia local em 14 voluntários sadios. Neste estudo randomizado, cruzado e duplo-cego, os voluntários receberam anestesia infiltrativa na maxila de ropivacaína a 0,5% encapsulada em lipossomas e ropivacaína 0,5% com epinefrina a 1:200.000 em duas sessões distintas. Amostr...

متن کامل

Experimental Study of a Flash-lamp Pumped Passively Q-Switched Nd:YAG Laser Using Cr4+:YAG Saturable Absorber

This paper deals with the experimental results of a xenon flash-lamp pumped passively Q-switched Nd:YAG laser using Cr4+:YAG saturable absorber. The need of a laser cavity to be integrated into a time-of-flight laser range finder is of great interest as an experimental investigation of several laser resonators. Two types of laser resonator, with different lengths, have been studied: the flat-fl...

متن کامل

Application of Haar and Mexican Hat Wavelets to Double Divisor-Ratio Spectra for the Multicomponent Determination of Ascorbic Acid, Acetylsalicylic Acid and Paracetamol in Effervescent Tablets

A determinação simultânea de ácido ascórbico (AA), ácido acetilsalicílico (ASP) e paracetamol (PAR) em misturas sintéticas e tabletes efervescentes foi realizada usando-se as técnicas de transformações de Haar e transformações de onda pequena tipo chapéu mexicano (HAAR-CWT e MEXH-CWT, respectivamente), juntamente com a técnica de divisor duplo. Os métodos de processamento de sinal são baseados ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013