A new biomedical sensor for measuring PCO2.

نویسندگان

  • Peyman Mirtaheri
  • Sverre Grimnes
  • Orjan G Martinsen
  • Tor Inge Tønnessen
چکیده

Measuring PCO2 (partial pressure of carbon dioxide) in an organ can enable early detection of ischemia. However, there are few clinical applicable solutions for measuring PCO2. Based upon the requirement for clinical applications, a conductivity based PCO2 sensor is proposed. A conductivity based PCO2 sensor measures conductance in an aqueous solution separated from the measured object by a gas-permeable membrane. A bridge design with two cavities is favored for such a sensor. A planar and a cylindrical macro prototype based upon the bridge design were studied. The design criteria were based on the contribution from the electrode polarization, stray capacitances, contact area with the sample and design ability to miniaturize the sensor. The cylindrical sensor is favored because of its large contact area and advantages for miniaturization. Further investigation has to be done to confirm the functionality of such a design in a miniaturized form and its clinical performance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel biomedical sensor for early detection of organ ischemia

Measuring PCO2 (partial pressure of carbon dioxide) in an organ can enableearly detection of ischemia. However, there are few clinical applicablesolutions for measuringPCO2. Based upon the requirement for clinicalapplications, a conductivity based PCO2 sensor is proposed. A conductivitybased PCO2 sensor measures conductance in an aqueous solution separatedfrom the me...

متن کامل

Design and Construction of a Novel Tactile Sensor for Measuring Contact-Force, Based on Piezoelectric Effect

In this paper, design and construction of a tactile sensor for measuring contact-force is presented. Mechanism of measuring contact-force in this tactile sensor is based on impedance changing of piezoelectric crystal and voltage of different points in circuit as a result of applying force on the crystal. By considering a specific point in the circuit and recording the changes of its voltage, ma...

متن کامل

Design, Modeling, and Construction of a New Tactile Sensor for Measuring Contact-Force

This paper presents the design, modeling, and testing of a flexible tactile sensor and its applications. This sensor is made of polymer materials and can detect the 2D surface texture image and contact-force estimation. The sensing mechanism is based on the novel contact deflection effect of a membrane. We measure the deflection of the membrane with measuring the strain in the membrane with emb...

متن کامل

Design and Construction of a New Capacitive Tactile Sensor for Measuring Normal Tactile Force

This paper presents the design, construction and testing of a new capacitive tactile sensor for measurement of normal tactile force. The operation of proposed sensor has been investigated in ASTABLE and MONOSTABLE circuits. According to the results of these circuits the deviation of ASTABLE circuit results is less than MONOSTABLE circuit results. In addition, the results obtained from ASTABLE c...

متن کامل

Application and assessment of a membrane-based pCO2 sensor under field and laboratory conditions

The principle, application, and assessment of the membrane-based ProOceanus CO2-Pro sensor for partial pressure of CO2 (pCO2) are presented. The performance of the sensor is evaluated extensively under field and laboratory conditions by comparing the sensor outputs with direct measurements from calibrated pCO2 measuring systems and the thermodynamic carbonate calculation of pCO2 from discrete s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physiological measurement

دوره 25 2  شماره 

صفحات  -

تاریخ انتشار 2004