Early micro-rheological consequences of single fraction total body low-dose photon irradiation in mice.

نویسندگان

  • Kornelia Szluha
  • Kornelia Lazanyi
  • Andrea Furka
  • Ferenc Kiss
  • Imre Szabo
  • Eva Pintye
  • Iren Miko
  • Norbert Nemeth
چکیده

Despite of the studies on widespread biological effects of irradiation, surprisingly only little number of papers can be found dealing with its in vivo hemorheological impact. Furthermore, other studies suggested that low-dose irradiation might differ from high-dose in more than linear ways. On Balb/c Jackson female adult mice hematological and hemorheological impacts of total body irradiation were investigated 1 hour following 0.002, 0.005, 0.01, 0.02, 0.05 and 0.1 Gy dose irradiation. In case of 0.01 Gy further groups were analyzed 30 minutes, 2, 4, 6, 24 and 48 h after irradiation. According to the results, it seems that the dose-dependent changes of blood micro-rheological parameters are not linear. The irradiation dose of 0.01 Gy acted as a point of 'inflexion', because by this dose we found the most expressed changes in hematological parameters, as well as in red blood cell aggregation, deformability and osmoscan data. The time-dependent changes showed progressive decrease in pH, rise in lactate concentration, further decrease in erythrocyte aggregation index and deformability, with moderate shifting of the optimal osmolarity point and modulation in membrane stability. As conclusion, low-dose total body irradiation may cause micro-rheological changes, being non-linearly correlated with the irradiation dose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rheological properties of blood after whole body gamma-irradiation

Background: The study of rheological properties of blood has special interest since it is a circulating fluid exposed to shear rates during its life time. This work aims to investigate the influence of whole body gamma irradiation on the rheological properties of rat’s blood. The applied shear rate was from 12 to 375 s-1. Low shear viscosity (up to 100 s-1) depends mainly on the erythroc...

متن کامل

Fabrication of anthropomorphic phantoms for use in total body photon irradiation and total skin electron irradiation studies

Introduction: Total Skin Electron Therapy (TSET) and Total Body Irradiation (TBI) are kinds of treatment which use electron and photon beams to treat special types of cancers. The aim of these techniques are to deliver uniform dose to the entire skin while minimizing delivered dose to organs at risk. To check the homogeneity of dose delivery in TBI and TSET, using a humanoid ph...

متن کامل

Impact of Prolonged Fraction Delivery Time Modelling Stereotactic Body Radiation Therapy with High Dose Hypofractionation on the Killing of Cultured ACHN Renal Cell Carcinoma Cell Line

Introduction: Stereotactic body radiotherapy delivers hypofractionated irradiation with high dose per fraction through complex treatment techniques. The increased complexity leads to longer dose delivery times for each fraction. The purpose of this study is to investigate the impact of prolonged fraction delivery time with high-dose hypofractionation on the killing of cultured ACHN cells.Method...

متن کامل

Trabecular bone changes induced by fast neutrons versus gamma rays in mice

Background: The trabecular bone changes in the tibia of C3H/HeN mice were measured 12 weeks after whole body irradiation with various doses of fast neutrons (0-2.4 Gy) or 137Cs-generated gamma-rays (0-6 Gy). Materials and Methods: Serum calcium, phosphorus, estradiol concentration and alkaline phosphatase activity were measured. Tibiae were anal...

متن کامل

Evaluation of dose uniformity in total body irradiation (TBI) technique in parallel-opposed anterior/posterior geometry using Varian Clinac 2100C/D linear accelerator

Background: Total body irradiation (TBI) is a technique that is commonly used as a part of the patient conditioning regimen before the bone marrow transplant (BMT). The purpose of this study is to introduce and implement a reasonable TBI technique on the human-like phantom in Imam Khomeini Hospital in Tehran. Methods: The present experimental study was conducted from October 2016 to November 2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical hemorheology and microcirculation

دوره 57 3  شماره 

صفحات  -

تاریخ انتشار 2014