False elevation of serum CA-125 level caused by human anti-mouse antibodies.
نویسندگان
چکیده
Discordant results were observed for serum CA-125 (carbohydrate antigen-125) assays in a patient who was monitored for recurrence of ovarian cancer. Serum CA-125 levels in this patient were normal when measured in one laboratory, but >5-times the upper limit of normal (35 U/mL) when measured in another laboratory. Both laboratories used dual antibody heterogeneous immunoassays, but from different manufacturers. Cross-linking heterophilic antibodies were suspected as a cause of the discrepancy, but the interference was not alleviated after 10-fold dilution. Assay of the patient's serum for human anti-mouse antibodies was positive, but only slightly above the reference range. Addition of blocking antibodies eliminated the interference, showing that human anti-mouse antibodies were the cause of the discrepant CA-125 results. These findings indicate that relatively low concentrations of human anti-mouse antibodies can cause significant interference in two-site immunoassays.
منابع مشابه
Evidence for interaction of human anti-idiotypic antibodies with CA 125 determination in a patient after radioimmunodetection.
Very high concentrations of CA 125 have been found in some ovarian cancer patients after repeated radioimmunodetection with anti-CA 125 antibodies [OC125-F(ab')2]. In one patient we measured a CA 125 concentration of 135,000 kilo-arb. units/L, using an enzyme immunoassay involving OC125 antibodies. With an immunoradiometric assay involving use of two new anti-CA 125 antibodies (B43.13 and B27.1...
متن کاملInterference by human anti-mouse antibodies in CA 125 assay after immunoscintigraphy: anti-idiotypic antibodies not neutralized by mouse IgG but removed by chromatography.
Falsely increased concentrations of the ovarian carcinoma-associated antigen, CA 125, were measured by a monoclonal antibody (MAb)-based double determinant immunoradiometric assay (IRMA) in patients who developed antibodies to mouse immunoglobulins (IgGs) after receiving injections of the same MAb as is used in the CA 125 IRMA. Addition of undiluted mouse serum or purified mouse IgG to the assa...
متن کاملMonitoring cancer antigen 125 in serum of ovarian cancer patients after administration of 131I-labeled F(ab')2 fragments of OC125 antibody.
We evaluated the effect of repeated administration of OC125 F(ab')2 fragments on cancer antigen (CA) 125 determination in 210 serum samples from 30 patients. We found falsely high CA 125 concentrations in 142 (68%) samples, using a homologous CA 125 enzyme immunoassay (EIA) with OC125 antibodies. The Truquant OV2 method, which involves two other murine antibodies, and the IMx CA 125 method, whi...
متن کاملConfirmation of a false-positive result in CA 125 immunoradiometric assay caused by human anti-idiotypic immunoglobulin.
An immunoradiometric assay (IRMA) involving a monoclonal antibody (MAb OC125) to an ovarian carcinoma-associated antigenic determinant (CA 125) has been tested as one component in a strategy for early detection of epithelial ovarian cancer. We characterized one confirmed "false-positive" sample by murine antibody blocking studies, Western blotting, immunoaffinity, size-exclusion chromatography,...
متن کاملHeterophilic antibodies in human sera causing falsely increased results in the CA 125 immunofluorometric assay.
An in-house OC 125 monoclonal antibody-based "sandwich" immunofluorometric assay (IFMA) described previously (Clin Chem 1987; 33:2191-4) gave higher results for CA 125 in 37 of 123 serum samples than did a commercially available immunoradiometric assay (IRMA). Discordant results between the two assays became concordant when measurements of the samples were repeated with normal mouse serum (100 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of clinical and laboratory science
دوره 32 4 شماره
صفحات -
تاریخ انتشار 2002