BACKGROUND Root canal preparation using rotary nickel-titanium instruments has been reported to be superior to hand instrumentation in terms of root canal shape, centring and frequency of procedural errors. The purpose of this study was to evaluate canal preparations using a sequential silicone impression technique to assess root canal morphology. METHODS Pre-operative canal impressions were obtained from 24 extracted single-rooted premolars. Canals were randomly assigned to be firstly, instrumented with stainless steel K-type files or rotary nickel-titanium instruments (Profile), then further apically enlarged with rotary nickel-titanium instruments (Profile or Lightspeed). Post instrumentation impressions were taken and digitally photographed in a bucco-lingual and mesio-distal orientation at low-power magnification. Images were evaluated for procedural defects, changes in canal curvature, canal enlargement and canal rounding at 1, 3 and 7mm from the working length. RESULTS Silicone impressions could accurately reproduce the detailed root canal morphology of single-canal premolars. Repeated impressions of each canal using a standardized procedure allowed a detailed comparison of instrumentation techniques at various stages. Hand instrumentation incurred more errors than rotary nickel-titanium instrumentation (Profile). Further apical enlargement using Lightspeed instruments incurred fewer errors than with Profile instruments. Differences among techniques were highly significant (p<0.005). All techniques resulted in slight canal straightening, as well as rounder and enlarged canals particularly in the apical third. CONCLUSIONS Rotary nickel-titanium instrumentation, especially Lightspeed, may produce better canal shape by reducing procedural errors.
منابع مشابه
A Comparison of Canal-centering ability of Two Nickel-Titanium Rotary Systems with Nickel Hand Instrumentation with Stainless Steel Hand Instrumentation in 10 to 25° Curved Canals using Kuttler's Cube
AIMS The purpose of this study was to compare the canal centering abilities of rotary nickel-titanium (NiTi) files (ProFile 0.04 and 0.06 and Lightspeed LSX) and NiTi hand K-files in 10° to 25° curved canals. This was compared with the canal centering ability of stainless steel hand K-files using Kuttler's endodontic cube. SETTINGS AND DESIGN The teeth with a 10° to 25° of clinical mesiodista...
متن کاملBacterial reduction with nickel-titanium rotary instrumentation.
The purpose of this study was to compare intracanal bacterial reduction on teeth instrumented with 0.04 tapered nickel-titanium (NiTi) rotary instrumentation to bacterial reduction when using a stainless-steel K-file step-back technique using sterile saline irrigation. Forty-eight patients with apical periodontitis were randomly assigned treatment type. The canals were sampled before, during, a...
متن کاملComparison of generated forces and apical microleakage using nickel-titanium and stainless steel finger spreaders in curved canals.
The purpose of this study was to compare (a) forces generated during lateral compaction and (b) apical microleakage for nickel-titanium (NiTi) and stainless steel (SS) finger spreaders. Twenty-eight extracted human teeth were instrumented using a standardized rotary instrumentation technique. NiTi and SS #30 spreaders were used to obturate molar roots while the forces generated during obturatio...
متن کاملSealing ability of lateral compaction and tapered single cone gutta-percha techniques in root canals prepared with stainless steel and rotary nickel titanium instruments
OBJECTIVES The aim of this study was to evaluate the sealing ability of lateral compaction and tapered single cone gutta-percha techniques in root canals prepared with stainless steel and rotary nickel titanium root canal instruments by fluid filtration method. STUDY DESIGN The root canals were prepared with stainless steel (SS) and nickel titanium (NiTi) instruments. The canals prepared with...
متن کاملA retrospective study of endodontic treatment outcome between nickel-titanium rotary and stainless steel hand filing techniques.
AIM The purpose of this study was to compare the periapical healing of molar root canal treatment using two instrumentation techniques. METHODS A total of 225 maxillary and mandibular first and second permanent molars endodontically treated by undergraduate or postgraduate students were randomly selected from a computerized hospital database of which 110 molars had been prepared using a hybri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Australian dental journal
دوره 47 1 شماره
صفحات -
تاریخ انتشار 2002