Estimating safe scaled distances for columns subjected to blast
نویسندگان
چکیده
This paper is concerned with determining the minimum stand-off distance required to prevent column failures in reinforced concrete framed buildings. This is of interest because column failures can initiate progressive collapse, resulting in mass casualties. A technique is developed to determine the critical range at which failure will occur for a given weight of explosives and thus provide a safe scaled distance. The method is used to carry out a parametric study of a range of reinforced concrete columns of variable dimensions and strengths. The corresponding data were used to predict safe scaled distances for columns (with and without clearing). These values can be used to estimate the minimum stand-off distance required to prevent progressive collapses of buildings that may be subjected to deliberate blast loading.
منابع مشابه
Finite Element Analysis for CFST Columns under Blast Loading
The columns of frame structures are the key load-bearing components and the exterior columns are susceptible to attack in terrorist blasts. When subjected to blast loads, the columns would suffer a loss of bearing capacity to a certain extent due to the damage imparted which may lead to their collapse and even cause the progressive collapse of the whole structure . The concrete-filled steel col...
متن کاملبررسی عملکرد ستونهای بتنی مقاوم سازی شده با صفحات FRP تحت اثر بارگذاری انفجاری
With the increase in the number of terrorist incidents worldwide, the resistance of structures, especially concrete structures, to explosions and their effectiveness under blast loads is of great importance. Over the past few decades, these terrorist attacks have left a lot of financial and human life damage around the world. The result of this event, have been Feeling the more need engineers f...
متن کاملMagnitude of vibration triggering component determines safety of structures
Transmission of blast waves is a complex phenomenon and the characteristics vary with blast design parameters and geo-technical properties of medium. Frequency of vibration and triggering component for structural excitation generally quantifies safe vibration magnitude. At closer distance or higher elevations than the blast locations, vertical or transverse component will be the first arrival t...
متن کاملارزیابی و مقایسهی رفتار ستونهای بتن مسلح دایرهای و مربعی تقویت شده با جاکتهای فولادی در برابر انفجار
Evaluation and Comparison of Behavior of Steel Jacketed RC Columns with Circular and Square Sections under Blast Loading Reinforced concrete (RC) structures are widely used in urban buildings and infrastructures, and these are always subjected to explosions caused by intentional or unintentional accidents. Among the structural members, columns are key load carrier elements. In this paper, b...
متن کاملEffects of Blast Vibration on Unplanned Dilution in an Underground Metal Mine
One of the factors affecting overbreak or slough of the roof and walls of underground stopes, causing unplanned dilution is blast vibration. The amount of damage caused by earth vibration can be measured in terms of peak particle velocity (PPV). In this study, in order to investigate the effects of blast vibration on the occurrence of unplanned dilution, 72 three-component records acquired upon...
متن کامل