Improvement of bias and generalizability for computer-aided diagnostic schemes

نویسنده

  • Qiang Li
چکیده

Computer-aided diagnostic (CAD) schemes have been developed for assisting radiologists in the detection of various lesions in medical images. The reliable evaluation of CAD schemes is as important as the development of such schemes in the field of CAD research. In the past, many evaluation approaches, such as the resubstitution, leave-one-out, cross-validation, and hold-out methods, have been proposed for evaluating the performance of various CAD schemes. However, some important issues in the evaluation of CAD schemes have not been analyzed systematically, either theoretically or experimentally. Such important issues include (1) the analysis and comparison of various evaluation methods in terms of some characteristics, in particular, the bias and the generalization performance of trained CAD schemes; (2) the analysis of pitfalls in the incorrect use of various evaluation methods and the effective approaches to reduction of the bias and variance caused by these pitfalls; (3) the improvement of generalizability for CAD schemes trained with limited datasets. This article consists of a series of three closely related studies that address the above three issues. We believe that this article will be useful to researchers in the field of CAD research who can improve the bias and generalizability of their CAD schemes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of the Different Primary Cancers and Different Types of Bone Metastasis on the Lesion-based Artificial Neural Network Value Calculated by a Computer-aided Diagnostic System,BONENAVI, on Bone Scintigraphy Images

Objective(s): BONENAVI, a computer-aided diagnostic system, is used in bone scintigraphy. This system provides the artificial neural network (ANN) and bone scan index (BSI) values. ANN is associated with the possibility of bone metastasis, while BSI is related to the amount of bone metastasis. The degree of uptake on bone scintigraphy can be affected by the type of bone metastasis. Therefore, t...

متن کامل

THE IMPACT OF USING COMPUTER-AIDED ARGUMENT MAPPING (CAAM) ON THE IMPROVEMENT OF IRANIAN EFL LEARNERS’ WRITING SELF-REGULATION

The present study was conducted to investigate the impact of using computer-aided argument mapping (CAAM) on the improvement of Iranian learners’ writing self-regulation. To this end, 90 participants out of 127 senior university students in English translation were selected after administrating language proficiency test, as well as an essay writing test for the purpose of homogenizing the learn...

متن کامل

Computerize classification of Benign and malignant thyroid nodules by ultrasound imaging

Introduction: Early detection and treatment of thyroid nodules increase the cure rate and provide optimal treatment. Ultrasound is the chosen imaging technique for assessment of thyroid nodules. Confirmation of the diagnosis usually demands repeated fine needle aspiration biopsy (FNAB). So, current management, has morbidity and non zero mortality. The goal of the present study ...

متن کامل

Survey on Perception of People Regarding Utilization of Computer Science & Information Technology in Manipulation of Big Data, Disease Detection & Drug Discovery

this research explores the manipulation of biomedical big data and diseases detection using automated computing mechanisms. As efficient and cost effective way to discover disease and drug is important for a society so computer aided automated system is a must. This paper aims to understand the importance of computer aided automated system among the people. The analysis result from collected da...

متن کامل

UWB Mixer improvement with Regulated Voltage Source

This paper presents a design of an UWB downconversion integrated CMOS resistive ring mixer with Linear Voltage Regulator (LVR), to supply required biasing voltages for the mixer section. The designed mixer circuit has been optimized for using in heart rate extraction system with microwave Doppler radar at 2.4GHz frequency. This mixer needs 2 DC bias voltages equal to 0.5 and 1 volts for its bes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society

دوره 31 4-5  شماره 

صفحات  -

تاریخ انتشار 2007