Safety and efficacy of VisuMax® circle patterns for flap creation and enhancement following small incision lenticule extraction

نویسندگان

  • Ekktet Chansue
  • Morakot Tanehsakdi
  • Sukanda Swasdibutra
  • Colm McAlinden
چکیده

BACKGROUND The purpose of this case series is to evaluate the safety and efficacy of VisuMax® Circle patterns in eyes that have undergone small incision lenticule extraction, thus creating a flap to perform an enhancement procedure or residual lenticule extraction. METHODS This prospective, single center, case study series evaluated the use of a VisuMax® Circle pattern to create a corneal flap following small incision lenticule extraction. Patients were treated and followed at TRSC International LASIK Center (Bangkok, Thailand) for 3 months to assess the efficacy and safety of the procedure. Efficacy was determined by the surgeon's ability to lift the created corneal flap. RESULTS The study enrolled 28 eyes. Twenty-seven underwent the VisuMax® Circle pattern procedure for refractive enhancement, and one for residual lenticule extraction. In 100 % of cases (28 eyes) the lifting of the flap was possible, as planned. In all cases of refractive enhancement (27 eyes) by laser in situ keratomileusis (LASIK), the exposure of the stromal bed was sufficient for the necessary excimer laser ablation. No eyes lost two or more Snellen lines of corrected distance visual acuity (CDVA) and no procedure or flap-related complications or serious adverse events occurred. CONCLUSIONS This initial case series demonstrates that VisuMax® Circle pattern is efficacious and a suitable method to create a corneal flap for enhancement, following small incision lenticule extraction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy, predictability and safety of small incision lenticule extraction (SMILE)

BACKGROUND The purpose of this case series is to report the one-year outcomes of small incision lenticule extraction (SMILE) using the VisuMax® femtosecond laser. METHODS Two hundred and six patients were recruited for this retrospective, single center study at TRSC International LASIK Center in Bangkok, Thailand. Patients underwent SMILE, whereby an intrastromal lenticule was cut using a fem...

متن کامل

Retreatment strategies following Small Incision Lenticule Extraction (SMILE): In vivo tissue responses

With any refractive correction, including Small Incision Lenticule Extraction (SMILE), there may be a residual refractive error that requires a retreatment. Here, we investigated the tissue responses following various retreatment procedures in a rabbit model of SMILE. All rabbits underwent a -6.00D correction with SMILE. Two weeks later, they underwent -1.00D enhancement by: (i) VisuMax Circle,...

متن کامل

Efficacy, safety, predictability, contrast sensitivity, and aberrations after femtosecond laser lenticule extraction.

PURPOSE To compare femtosecond lenticule extraction and small-incision lenticule extraction to treat moderate to high myopia. SETTING Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark. DESIGN Prospective clinical single-masked paired-eye study. METHODS An intrastromal lenticule was cut by a femtosecond laser and manually extracted. In femtosecond lenticule extractio...

متن کامل

Erratum for "Femtosecond Laser-Assisted Keyhole Endokeratophakia: Correction of Hyperopia by Implantation of an Allogeneic Lenticule Obtained by SMILE From a Myopic Donor".

PURPOSE To describe endokeratophakia in which a small incision lenticule extraction (SMILE) lenticule from a myopic patient is implanted into a recipient eye through a small incision to correct hyperopia. METHODS A 23-year-old aphakic woman presented following cataract surgery to remove a childhood congenital cataract with hyperopia of +12.00 -1.50 × 155, corrected distance visual acuity of c...

متن کامل

Small incision lenticule extraction (SMILE) history, fundamentals of a new refractive surgery technique and clinical outcomes

This review summarizes the current status of the small incision lenticule extraction (SMILE) procedure. Following the early work by Sekundo et al. and Shah et al., SMILE has become increasingly popular. The accuracy of the creation of the lenticule with the VisuMax femtosecond laser (Carl Zeiss Meditec) has been verified using very high-frequency (VHF) digital ultrasound and optical coherence t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2015