Valve-in-valve in the tricuspid position for a stenosed bioprosthesis.

نویسندگان

  • Ziv Beckerman
  • Oved Cohen
  • Yoram Agmon
  • Gil Bolotin
چکیده

The strategy of transcatheter valve-in-valve implantation into failing mitral and aortic bioprosthetic valves is a documented approach. It allows one to avoid performing a high-risk repeat cardiac surgery in elderly patients with multiple comorbidities. Tricuspid valve-in-valve implantation has been documented only a few times in the literature. We report the case of a 65-year-old woman with a failing bioprosthetic tricuspid valve who had undergone 3 prior open heart operations. We attempted a transatrial transcatheter approach and successfully deployed a 29-mm Edwards Sapien balloon-expandable bioprosthesis into a severely stenotic tricuspid bioprosthesis. This case demonstrates the technical feasibility and safety of this approach.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Balloon dilatation of a stenosed bioprosthesis in the tricuspid valve position.

Percutaneous balloon dilatation of a stenosed Ionescu-Shiley bioprosthesis in the tricuspid valve position was performed twice in a 19 year old woman. On each occasion there was a considerable improvement in symptoms and haemodynamic function but the effect lasted for only a few months. When the valve was excised it showed no evidence of the previous balloon dilatations.

متن کامل

Right sided heart evaluation after successful mitral valve replacement.

Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...

متن کامل

Percutaneous tricuspid valve replacement for a stenosed bioprosthesis.

Percutaneous replacement of the aortic and pulmonic valves has rapidly gained acceptance in clinical practice as a feasible alternative to open valve surgery in patients deemed to be at high operative risk.1,2 Total percutaneous tricuspid valve replacement (TVR), on the other hand, has not yet been documented in humans, although this approach has been described in experimental animals.3 Webb et...

متن کامل

Noninvasive pacing during transfemoral implantation of the Edwards SAPIEN valve for tricuspid valve bioprosthesis stenosis

Introduction Transcatheter implantation of balloon expandable valves in high-risk patients with degenerated tricuspid bioprostheses has been reported since 2010 [1, 2]. Although there have been cases where the SAPIEN valve was implanted in the tricuspid position without rapid pacing [3, 4], invasive rapid ventricular pacing is usually applied during valve deployment. We present a case report do...

متن کامل

Effectiveness of balloon valvuloplasty for stenosis of a bioprosthesis in the tricuspid valve position.

A 67-year-old man underwent percutaneous balloon valvuloplasty for bioprosthetic tricuspid stenosis. He had undergone two tricuspid valve replacements over a period of 39 years and became symptomatic. After the valvuloplasty, his symptoms were resolved. Stenosis of a bioprosthetic tricuspid valve can be successfully and safely treated with balloon valvuloplasty.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The heart surgery forum

دوره 16 2  شماره 

صفحات  -

تاریخ انتشار 2013