Three of 7 hemoglobin A1c point-of-care instruments do not meet generally accepted analytical performance criteria.
نویسندگان
چکیده
BACKGROUND In 2009, we investigated the conformance of 8 hemoglobin A(1c) (Hb A(1c)) point-of-care (POC) instruments. Since then, instruments have improved and new devices are available on the market. In this second study, we evaluated the performance of DCA Vantage, Afinion, InnovaStar, Quo-Lab, Quo-Test, Cobas B101, and B-analyst Hb A(1c) POC instruments. METHODS Clinical and Laboratory Standards Institute protocols EP-5 and EP-9 were applied to investigate imprecision, accuracy, and bias. We assessed bias using the mean of 3 certified secondary reference measurement procedures (SRMPs). Assay conformance with the National Glycohemoglobin Standardization Program (NGSP) certification criteria was also evaluated. Interference of common Hb variants was investigated for methods that could work with hemolysed material. RESULTS The total CVs for all instruments, except for the DCA Vantage at a high Hb A(1c) value, were ≤3.1% in SI units and ≤2.1% in Diabetes Control and Complications Trial (DCCT) units. Afinion, DCA Vantage, B-analyst, and Cobas B101 instruments passed the NGSP criteria with 2 different reagent lot numbers. Quo-Test, Quo-Lab, and InnovaStar instruments had a negative bias compared to the mean of the 3 SRMPs and failed NGSP criteria. Most of the common Hb variants did not interfere with the investigated instruments, except Hb AE for the Cobas B101. CONCLUSIONS Afinion, DCA Vantage, Cobas B101, and B-analyst instruments met the generally accepted performance criteria for Hb A(1c). Quo-Test, Quo-Lab, and InnovaStar met the criteria for precision but not for bias. Proficiency testing should be mandated for users of Hb A1c POC assays to ensure quality.
منابع مشابه
Six of eight hemoglobin A1c point-of-care instruments do not meet the general accepted analytical performance criteria.
BACKGROUND Hemoglobin A(1c) (Hb A(1c)) point-of-care (POC) instruments are widely used to provide rapid-turnaround results in diabetic care centers. We investigated the conformance of various Hb A(1c) POC instruments (In2it from Bio-Rad, DCA Vantage from Siemens, Afinion and Nycocard from Axis-Shield, Clover from Infopia, InnovaStar from DiaSys, A1CNow from Bayer, and Quo-Test from Quotient Dia...
متن کاملDiagnosing diabetes mellitus: performance of hemoglobin A1c point-of-care instruments in general practice offices.
BACKGROUND Hemoglobin A1c (Hb A1c) measurement by hospital laboratory instruments, but not by point-of-care (POC) instruments, has been recommended for use to diagnose diabetes mellitus. We evaluated results from 13 Hb A1c external quality assurance (EQA) surveys over a 6-year period in Norway, from both POC instruments used in general practice (GP) offices and instruments in hospital laborator...
متن کاملCorrelation between Standard Clinical Chemistry and Point of Care Testing Analyzers on Hemoglobin A1C Determination
متن کامل
Few point-of-care hemoglobin A1c assay methods meet clinical needs.
Accurate and timely measurements of hemoglobin A1c (Hb A1c) 2 are an increasingly important challenge for clinical laboratories. As Hb A1c measurements are being used to answer new clinical questions, each new use of Hb A1c imposes requirements for the analytical performance of the methods used to measure it. Until recently, Hb A1c was used only as a key test for monitoring glycemic control in ...
متن کاملبررسی شاخص های مرتبط با کیفیت مراقبت بیماران دیابتی تحت پوشش برنامه پزشک خانواده روستایی شهرستان ارومیه در سال 1396
Background & Aims: More than 382 million people in the world live with diabetes, 80% of whom live in low-income and developing countries. Today, it is quite clear that improving metabolic control in diabetic patients can reduce the complications of the disease. The purpose of this study was to evaluate the quality of care associated with diabetic patients under the coverage of Urmia rural famil...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 60 8 شماره
صفحات -
تاریخ انتشار 2014