Lens epithelial cell ongrowth: comparison of 6 types of hydrophilic intraocular lens models.

نویسندگان

  • Gebtraud Schild
  • Jörg Schauersberger
  • Michael Amon
  • Claudette Abela-Formanek
  • Andreas Kruger
چکیده

PURPOSE To compare the ongrowth of lens epithelial cells (LECs) on the anterior surface of 6 different hydrophilic intraocular lenses (IOLs). SETTING Medical University of Vienna, Department of Ophthalmology and Optometry, Vienna, Austria. METHODS Six models of hydrophilic IOLs were compared in this prospective study: Visionflex A-100 (Distra Softcryl), Rayner Centerflex 570H (Rayner), Collamer CC4204BF-IOL (Staar), Injectacryl F 3000 (Distra), Hydroview H60M (Bausch & Lomb), and MemoryLens (ORC). Postoperative biomicroscopic examinations were performed 1, 3, 7, 30, 90, 180, and 365 days after surgery. Lens epithelial cells in each quadrant of the anterior capsule-free lens surface were graded. The product with the highest density and the number of quadrants with this density were used to measure LEC ongrowth. RESULTS The Hydroview and Visionflex IOLs showed significantly more LECs than the other IOLs starting on day 7 after surgery (P < .028). There was a statistically significant difference in LEC ongrowth on the Memory IOL compared with all other IOLs from day 30 onward (P < .001). The Rayner, Collamer and Injectacryl IOLs had the fewest LECs on the anterior surface compared with all other IOLs from day 7 until the final examination. CONCLUSIONS The findings show that LEC ongrowth on the IOL surface is material dependent. The findings suggest that the material of the recently developed hydrophilic IOLs induces less LEC ongrowth than older models.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biocompatibility of Intraocular Lenses

The performance of an intraocular lens is determined by several factors such as the surgical technique, surgical complications, intraocular lens biomaterial and design, and host reaction to the lens. The factor indicating the biocompatibility of an intraocular lens is the behavior of inflammatory and lens epithelial cells. Hence, the biocompatibility of intraocular lens materials is assessed in...

متن کامل

An in vitro study of human lens epithelial cell adhesion to intraocular lenses with and without a fibronectin coating.

PURPOSE To demonstrate differences in human lens epithelial cell adhesion to different intraocular lens biomaterials in vitro and to determine whether these differences can be influenced by coating the intraocular lens surface with commercially available fibronectin. METHODS A prospective laboratory-based study comparing human lens epithelial cell adhesion to silicone (n=18), polymethylmethac...

متن کامل

Comparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery

BACKGROUND Posterior capsular opacification (PCO) is a common long-term complication of cataract surgery. Intraocular lens design and material have been implicated in influencing the development of PCO. This study evaluated the association of hydrophobic and hydrophilic intraocular lenses on preventing PCO. METHODS Medline, Cochrane, EMBASE, and Google Scholar databases were searched until Au...

متن کامل

Pediatric cataract surgery with hydrophilic acrylic intraocular lens implantation in Nepalese children

Purpose To assess the outcome of cataract surgery with hydrophilic acrylic intraocular lens (IOL) implantation in children with congenital and developmental cataracts. Method A retrospective review of medical records of children with congenital or developmental cataracts who underwent cataract surgery with hydrophilic IOL implantation, from January 2011 to December 2014 in a tertiary eye hosp...

متن کامل

Treatment of ophidism-induced bilateral canine cataract by extracapsular lens extraction and intraocular lens implantation

The aim of this study was to report a new cause of cataract, namely snake bite induced cataract in a dog. A 3-year-old male mongrel dog was referred to our clinic for the assessment of cataract in both eyes. The dog was bitten by a snake nearly 4 months ago. A 40 dioptre acrylic lens with 13 mm haptics was implanted into the lens capsule. In the left eye, posterior synechia was detected in the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 31 12  شماره 

صفحات  -

تاریخ انتشار 2005