Comparison of fluorescence polarization immunoassay and enzyme immunoassay for free carbamazepine in serum or plasma ultrafiltrates from epileptic patients.
نویسنده
چکیده
CLINICAL CHEMISTRY, Vol. 30, No.8, 1984 1425 bined isoenzyme analysis using the DuPont aca analyzer to measure CKMB and LDH1. InBiologieProspective. ComptRenddu5 Colloq de Pont-d-Mou8son, MM Galteau, G Sleet, J Henny, Eds., Masson, Paris, 1983, pp 627-630. 8. McCoy MT. Aguanno JJ, Ritzms nn SE. Lactate dehydrogenase isoenzyme 1. A rapid assay for ischemic myocardial disease. Arch Intern Med 143, 434-436 (1983). 9. Belding RC, Reynoso G. An evaluation of the immunochemical LD-1 method in routine clinical practice. Clin Biochem 16,296298 (1983). 10 Ewen LM. Lactate dehydrogenase isoenzyme 1: Its usefulness as a screening test in diagnosis of myocardial infarction. Clin Biochem 16,306-309(1983). 11. Seckinger DL, Vazquez DA, Rosenthal PK, Mendizabal RC. Cardiac isoenzyme methodology and the diagnosis of acute myocardial infarction. Am J Clin Pathol 80, 164-169 (1983).
منابع مشابه
Fluorescence polarization immunoassay and enzyme immunoassay compared for free valproic acid in serum ultrafiltrates from epileptic patients.
Valproic acid (VPA; Depakene#{174}; Depakote#{174}) is indicated for use both as the sole and adjunctive therapy in the treatment of simple (petit mal) and complex absence seizures. It may also be used adjunctively in patients with multiple seizure types, which includes absence seizures. Adjustment of VPA dosage in patients with convulsive disorders is routinely guided by measurements of total ...
متن کاملSalivary free concentrations of anti-epileptic drugs: an evaluation in a routine clinical setting.
OBJECTIVE This study was aimed at correlating the salivary and serum free concentrations of anti-epileptic drugs (carbamazepine, phenytoin and sodium valproate) in a population of neurological patients in a routine clinical setting. METHOD Twenty-seven paired serum/saliva specimens from 22 patients: 10 for carbamazepine, 8 for phenytoin and 9 for sodium valproate were obtained to study these ...
متن کاملCan a single measurement of carbamazepine suffice for therapeutic monitoring?
Using fluorescence polarization immunoassay, we measured the peak and trough concentrations of total and free carbamazepine in serum and saliva from 33 epileptic children. We found that, except for patients who show side effects, measurement of trough values in a single sample, collected after an overnight fast and before the morning dose, sufficiently estimates clinical response. Moreover, tot...
متن کاملComparison of Valproic acid Clearance between Epileptic Patients and Patients with Acute Mania
Objective(s) The purpose of this study was assessment of the influence of acute manic phase on the steady state pharmacokinetics of valproic acid (VPA) in bipolar patients in comparison with those of epileptic patients. Materials and Methods Ninteen acutely manic and 25 epileptic patients who fulfilled inclusion and exclusion criteria were entered in this prospective study. Blood samples were...
متن کاملAutomated homogeneous liposome immunoassay systems for anticonvulsant drugs.
We developed automated homogeneous immunoassays, based on immunolysis of liposomes, for measuring phenytoin, phenobarbital, and carbamazepine from serum. Liposome lysis was detected spectrophotometrically from entrapped glucose-6-phosphate dehydrogenase activity. The procedure was fully automated on a routine automated clinical analyzer. Within-run, between-run, dilution, and recovery tests sho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 30 8 شماره
صفحات -
تاریخ انتشار 1984