Novel xenon calibration scheme for two-photon absorption laser induced fluorescence of hydrogen.
نویسندگان
چکیده
Two photon absorption laser induced fluorescence (TALIF) measurements of neutral hydrogen and its isotopes are typically calibrated by performing TALIF measurements on krypton with the same diagnostic system and using the known ratio of the absorption cross sections [K. Niemi et al., J. Phys. D 34, 2330 (2001)]. Here we present the measurements of a new calibration method based on a ground state xenon scheme for which the fluorescent emission wavelength is nearly identical to that of hydrogen, thereby eliminating chromatic effects in the collection optics and simplifying detector calibration. We determine that the ratio of the TALIF cross sections of xenon and hydrogen is 0.024 ± 0.001.
منابع مشابه
Arc Heated Wind Tunnel Flow Diagnostics using Laser-Induced Fluorescence of Atomic Species
Two-photon Laser induced fluorescence diagnostics system for atomic oxygen has been installed at the 750kW arc heated wind tunnel in JAXA in order to obtain velocity, translational temperature, and number density of atomic oxygen simultaneously. It was observed that the center of excitation wavelength is shifted in the shock layer. The Doppler shift due to the free stream velocity has a same or...
متن کاملTwo photon absorption laser induced fluorescence measurements of neutral density in a helicon plasma
We have developed a new diagnostic based on two-photon absorption laser induced fluorescence (TALIF). We use a high intensity (5 MW/cm), narrow bandwidth (0.1 cm ) laser to probe the ground state of neutral hydrogen, deuterium and krypton with spatial resolution better than 0.2 cm, a time resolution of 10 ns, and a measurement cadence of 20 Hz. Here, we describe proof-of-principle measurements ...
متن کاملTwo-Photon Absorption Laser Induced Fluorescence of Atomic Nitrogen by an Alternative Excitation Scheme
A two-photon absorption laser induced fluorescence (TALIF) scheme to monitor ground state atomic nitrogen is described. Excitation at 207 nm to the (3p) S3/2 upper state is demonstrated to be superior to the traditional 211 nm excitation to (3p) D7/2 . Most striking is the low quenching rate of the upper (3p) S3/2 state by N2 at kq = 6.7(9)x10 −11 cm3/s, nearly an order of magnitude lower than ...
متن کاملTwo Photon Absorption Laser Induced Fluorescence for Fusion Class Plasmas
Two Photon Absorption Laser Induced Fluorescence for Fusion Class Plasmas
متن کاملTWO PHOTON TRANSITIONS IN THE OPTOGALVANIC SPECTRUM OF NEON
Seventeen two-photon transitions for neon have been observed in the 580- 635 nm spectral region for use in the spectroscopic study of its higher excited levels, which are not accessible by one-photon absorption. To compare the two and one-photon absorption signals originating from the same lower level, an effort was made to record single-photon optogalvanic spectrum in the available wavele...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 87 11 شماره
صفحات -
تاریخ انتشار 2016