Study of plasma dynamics in a modulated pulsed power magnetron discharge using a time-resolved Langmuir probe

نویسندگان

  • L. Meng
  • D. N. Ruzic
چکیده

Modulated pulse power MPP technology is a derivative of high power pulsed magnetron sputtering that allows unprecedented user control over the growth process, although the critical time-dependent plasma properties during the power pulse have not been studied until now. Using a MPP plasma generator, pulses of custom voltage waveforms were generated and applied to the cathode of a 36 cm diameter circular planar magnetron. The I-V characteristics of the pulses are separable into distinct discharge stages. A time-resolved triple Langmuir probe was introduced to measure the temporal evolution of the plasma. Typical electron density of 5 1017 m−3 and electron temperature of 10 eV during the pulse were calculated from measured parameters. Plasma behaviors were observed to closely depend on the pulse waveforms. Various parameters, including pulse current, pulse frequency, pressure, and distance from the target, also affected the electron density and temperature, providing degrees of freedom to optimize the sputtering processes. The effects of each parameter on the pulsed plasma dynamics are discussed and then attributed to mechanisms of electron impact ionization, gas heating, and magnetic confinement. © 2011 American Vacuum Society. DOI: 10.1116/1.3528940

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of O2 and N2 Concentrations on the Characteristics of Plasma in DC Cylindrical Magnetron Discharge by Langmuir Probe

Using the Langmuir probe method, the reactive plasma parameters were studied in different ratios of oxygen and nitrogen concentrations in a DC cylindrical discharge device.The plasma parameters such as plasma potential, electron density and electron temperature wereextracted from the current-voltage characteristic’s curve of Langmuir probe to find the optimum conditions for deposit the oxy...

متن کامل

Emissive sheath measurements in the afterglow of a radio frequency plasma

Articles you may be interested in Negative plasma potential in a multidipole chamber with a dielectric coated plasma boundary Measurement of plasma-surface energy fluxes in an argon rf-discharge by means of calorimetric probes and fluorescent microparticles Time-resolved measurements of the E-to-H mode transition in electronegative pulse-modulated inductively coupled plasmas Time evolution of e...

متن کامل

Towards deeper understanding of an HiPIMS discharge by time-resolved optical plasma diagnostics

As a promising pulsed sputter deposition technique, High-Power Impulse Magnetron Sputtering (HiPIMS) required an extensive time-resolved plasma characterization. Being essentially non-intrusive, optical plasma diagnostics methods posses in particular the timeand spaceresolution(s) which normally exceed the typical needs of a typical HiPIMS geometry [1] and, therefore, can be readily applied for...

متن کامل

Double Langmuir probe measurement of plasma parameters in a dc glow discharge

In this paper, plasma main characteristics such as electron mean temperature, electron number density, and oscillation frequency have been measured experimentally using the double Langmuir probe diagnostic system. In our experiment, the plasma was generated by applying the low pressure dc glow discharge in several common gases. The experimental results indicated the highest plasma density and o...

متن کامل

Time and energy resolved ion mass spectroscopy studies of the ion flux during high power pulsed magnetron sputtering of Cr in Ar and Ar/N2 atmospheres

Mass spectroscopy was used to analyze the energy and composition of the ion flux during high power pulsed magnetron sputtering (HIPIMS/HPPMS) of a Cr target in an industrial deposition system. The ion energy distribution functions were recorded in the time-averaged and time-resolved mode for Ar + , Ar 2+ , Cr + , Cr 2+ , N2 + and N + ions. In the metallic mode the dependence on pulse energy (eq...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011