Sirolimus versus bare metal stent implantation in patients with total coronary occlusions: subgroup analysis of the Stenting Coronary Arteries in Non-Stress/Benestent Disease (SCANDSTENT) trial.

نویسندگان

  • Henning Kelbaek
  • Steffen Helqvist
  • Leif Thuesen
  • Lene Kløvgaard
  • Erik Jørgensen
  • Kari Saunamäki
  • Lars R Krusell
  • Hans E Bøtker
  • Thomas Engstrøm
  • Gunnar V H Jensen
چکیده

BACKGROUND Coronary restenosis is more common in a total coronary occlusion (TCO) than other lesion types after implantation of bare metal stents (BMS). But whereas sirolimus-eluting stents (SES) have been shown to improve the outcomes in simple coronary artery lesions, data on their efficacy in complex coronary lesions are scarce. METHODS We enrolled 127 patients with coronary artery disease and a TCO > or = 15 mm in length to have either SES or BMS implanted after successful recanalization. Outcome measures included the minimal lumen diameter, the late lumen loss, and angiographic restenosis (> 50% diameter stenosis) at 6 months follow-up and the occurrence of target vessel failure during a 7-month period. RESULTS The patients were well matched in demographic and angiographic baseline characteristics, and 20% had diabetes. The reference vessel was 2.92 mm in mean, and the lesion length was 25.2 mm. At follow-up, patients who received SES had a minimal lumen diameter of 2.49 mm compared with 1.46 mm in those who received BMS (P = .015), 0% versus 38% developed restenosis (P < .001), lumen loss was -0.05 versus 0.99 mm (P < .001), and the target vessel failure rate 5% with SES versus 35% with BMS (P < .001). Stent thrombosis occurred in 1 patient in the BMS group. CONCLUSIONS Implantation of SES is safe, and it markedly reduces angiographic restenosis and the occurrence of adverse events in patients with a TCO.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Primary Stenting of Totally Occluded Native Coronary Arteries II (PRISON II): a randomized comparison of bare metal stent implantation with sirolimus-eluting stent implantation for the treatment of total coronary occlusions.

BACKGROUND Sirolimus-eluting stents markedly reduce the risk of restenosis compared with bare metal stents. However, it is not known whether there are differences in effectiveness between bare metal and sirolimus-eluting stents in patients with total coronary occlusions. METHODS AND RESULTS In a prospective, randomized, single-blind, 2-center trial, we enrolled 200 patients with total coronar...

متن کامل

Three overlapping septal occlusion devices to treat residual shunting across an atrial septal defect.

Saunamäki K, Krusell LR, Jensen GVH, Bøtker HE, Lassen JF, Andersen HR, Thayssen P, Galløe A, van Weert A, for the SCANDSTENT Investigators. A randomized multicenter comparison of sirolimus versus bare metal stent implantation in complex coronary artery lesions. Results from the SCANDSTENT trial. J Am Coll Cardiol 2006;47:449–455. 8. Tsuchida K, Colombo A, Lefèvre T, Oldroyd KG, Guetta V, Guagl...

متن کامل

بررسی نتیجه کلینیکی بلند مدت آنژیوپلاستی با استنت فلزی در بیماران مبتلا به بیماری عروق کرونر در بیمارستان فاطمه زهرا (س) ساری از سال 1383 تا سال 1385

Background and Purpose:Coronary artery Stenting is known to improve the outcome for ischemic heart disease. Many clinical studies have been performed to determine the long-term outcome of coronary Stenting and most of them were based on first-generation bare-metal Stents. The aim of this study is to evaluate long-term (24 6.4 month) results of second-generation bare metal stent. Materials an...

متن کامل

Evaluation of the haemodynamic characteristics of drug-eluting stents at implantation and at follow-up.

AIMS The aim of this study was to investigate the physiologic parameters: fractional flow reserve (FFR), hyperaemic trans-stent gradient (HTG), and wall shear stress (WSS) at implantation and at 6-month follow-up in the drug-eluting sirolimus stent and in its bare metal counterpart implanted in pairs within the same patient. METHODS AND RESULTS Twenty patients, accepted for percutaneous coron...

متن کامل

The stenting strategy of drug-eluting stents for coronary artery disease in patients on dialysis

BACKGROUND Reports regarding the relationship between the length and diameter of implanted drug-eluting stents and clinical and angiographic outcomes in dialysis patients are limited. AIM We investigated the efficiency of drug-eluting stents for coronary artery disease in patients on dialysis from the viewpoint of stent sizing. METHODS Sirolimus-eluting stents were implanted in 88 lesions a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American heart journal

دوره 152 5  شماره 

صفحات  -

تاریخ انتشار 2006