Rapid analysis of hemoglobin variants by cation-exchange HPLC.
نویسندگان
چکیده
We investigated the use of a 3.5 x 0.46 cm HPLC column packed with 5-microns particles of porous (100 nm) silica coated with polyaspartic acid for hemoglobin analysis. A 13-min gradient was produced between two mobile phases. The method is capable of separating more than 35 commonly encountered hemoglobin variants within 12 min. Hemoglobin variants identified include Bart's, acetyl F, H, A1c, F, Camden, N-Baltimore, J-Baltimore, N-Seattle, Grady, Fannin-Lubbock, A G-Georgia, Lepore-Baltimore, P-Galveston, G-Coushatta, Lepore-Boston, E, Osu Christiansborg, A2, G-Philadelphia, Korle Bu, Russ, Richmond, D-Los Angeles, Deer Lodge, Montgomery, S, Q-Thailand, G-San Jose, A2', Hasharon, Q-India, Tampa, GS hybrid, C-Harlem, O-Arab, British Columbia, and C. Between-run precision of an in-house pooled hemoglobin control material, AFSCA2, gave CVs of 2-5% for the A, F, S, and C and 8% for the A2 over a 6-month period. The simplicity of sample preparation, high resolution of the system, and high accuracy of the method, combined with complete automation, make this an ideal methodology for the routine diagnosis of hemoglobin disorders in a clinical laboratory.
منابع مشابه
Capillary isoelectric focusing and high-performance cation-exchange chromatography compared for qualitative and quantitative analysis of hemoglobin variants.
We have developed two assays for complete analysis of hemoglobins (Hbs) in the field of hemoglobinopathies: a high-performance cation-exchange liquid chromatography (HPLC) assay on the weak cation-exchanger Poly Cat A and a two-step capillary isoelectric focusing (CIEF) assay on the neutral-coated capillary from Beckman in a narrow pH gradient. The resolution was satisfactory for both HPLC and ...
متن کاملCation-exchange HPLC evaluated for presumptive identification of hemoglobin variants.
A battery of relatively simple tests allows the presumptive identification of hemoglobin (Hb) variants, making unnecessary structural analysis by protein chemistry methods or DNA sequencing. The primary step in this strategy involves the use of a matrix of electrophoretic mobilities obtained under various experimental conditions. This leads to an unambiguous result in approximately 90% of the c...
متن کاملMass spectrometry: a tool for enhanced detection of hemoglobin variants.
BACKGROUND More than 900 hemoglobin (Hb) variants are currently known. Common techniques used in Hb analysis are electrophoretic and chromatographic assays. In our laboratory, we routinely apply chromatographic methods. To ascertain whether Hb variants are missed with our procedures, we additionally analyzed all samples with mass spectrometry (MS). METHODS Database evaluation was performed us...
متن کاملCOMPARISON OF CATION EXCHAGE HPLC AND IMMUNOTURBIDIMETRIC METHOD FOR DETERMINATION OF HbA1c
Objective: The objective of this study was to compare and correlate the analytical performance of D10 Hemoglobin Testing System based on Cation Exchange HPLC and Roche Hitachi 902 Immunoturbidimetric method. Subjects and Methods: A total of 110 patients of Type 2 Diabetes Mellitus were included in the study. HbA1c was determined using D-10 Hemoglobin Testing system and Roche Hitachi 902 Analyze...
متن کاملSpectrum of haemoglobinopathies diagnosed by cation exchange-HPLC & modulating effects of nutritional deficiency anaemias from north India
BACKGROUND & OBJECTIVES The usefulness of cation exchange high performance liquid chromatography (CE-HPLC) as a tool for detection of thalassaemia/haemoglobin variants was evaluated in a prospective study in a tertiary care centre in north India. We also tried to evaluate the effect of concurrent nutritional deficiency on the HPLC pattern in the local ethnic population. METHODS A total of 800...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 39 5 شماره
صفحات -
تاریخ انتشار 1993