The Effects of Endotracheal Tube and i-gel® Supraglottic Airway Device on Respiratory Impedance: A Prospective Observational Study

نویسندگان

  • Shoko Nakano
  • Junko Nakahira
  • Yosuke Kuzukawa
  • Toshiyuki Sawai
  • Toshiaki Minami
چکیده

BACKGROUND The forced oscillation technique (FOT) is a non-invasive means of measuring respiratory resistance and reactance. We tested our hypothesis that endotracheal intubation would cause more substantial preoperative increases in FOT parameters than a supraglottic airway device (SGD). METHODS Forty patients requiring general anesthesia and mechanical ventilation for transurethral bladder tumor resection underwent spirometry the day before surgery. Forced oscillation was measured using a MostGraph-01 device the day before surgery and immediately after removal of the airway adjunct. Changes in respiratory resistance and reactance were compared between those intubated and those who used SGD. RESULTS The trachea was intubated in 23 patients and SGD was used in the remaining 17 patients. Both airway adjuncts caused significant increases in preoperative respiratory resistance and reactance; however, the magnitude of the changes was significantly greater in the intubated patients. CONCLUSIONS The SGD appears to cause less pulmonary injury than tracheal intubation. Further study is needed to illuminate the influence of mechanical ventilation, and longer-term consequences and clinical significance of the changes we found in this study. Spontaneous ventilation through an SGD may be preferable in patients with severe respiratory disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries

Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...

متن کامل

A Prospective Randomized Comparative Study on i-gel versus Laryngeal Mask Airway Fastrach as a Conduit for Blind Tracheal Intubation Using Conventional PVC Endotracheal Tubes in Reverse Orientation

Introduction: Laryngeal mask airway (LMA) Fastrach was specially designed as a conduit for blind tracheal intubation in anticipated difficult airway and where we do not require neck extension. i-gel is a disposable, cheap supraglottic device with wide bore stem which facilitates direct passage of a conventional polyvinylchloride (PVC) endotracheal tube. Materials and Methods: A total of 80 adul...

متن کامل

Success Rate of Airway Devices Insertion: Laryngeal Mask Airway Versus Supraglottic Gel Device

BACKGROUND The main important method for airway management during anesthesia is endotracheal intubation. Laryngeal mask airway (LMA) and supraglottic gel device (I-Gel) are considered alternatives to endotracheal tube. OBJECTIVES This study sought to assess the success rate of airway management using LMA and I-Gel in elective orthopedic surgery. PATIENTS AND METHODS This single-blinded rand...

متن کامل

A comparative Study of Tracheal Intubation through i-gel® and Intubating

In this prospective randomized study, success rate of blind tracheal intubation through two different supraglottic airway devices viz. i-gel ® and the intubating laryngeal mask airway (ILMA)® was compared a using conventional polyvinylchloride endotracheal tubes. Eighty patients undergoing elective surgery under general anaesthesia were randomized in two groups comprising of 40 patients each to...

متن کامل

I-Gel is a suitable alternative to endotracheal tubes in the laparoscopic pneumoperitoneum and trendelenburg position

BACKGROUND The use of supraglottic airway devices (SADs) in surgeries with laparoscopic pneumoperitoneum and Trendelenburg (LPT) positioning is controversial due to concerns about insufficient pulmonary ventilation and aspiration. In this prospective, randomized-controlled trial, we evaluated whether the i-gel, a new second generation SAD, provides an effective alternative to an endotracheal tu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017