Amperometric glucose sensor based on glucose oxidase immobilized on gelatin-multiwalled carbon nanotube modified glassy carbon electrode.

نویسندگان

  • Arun Prakash Periasamy
  • Yu-Jung Chang
  • Shen-Ming Chen
چکیده

We investigated the direct electrochemistry of glucose oxidase (GOx) at gelatin-multiwalled carbon nanotube (GCNT) modified glassy carbon electrode (GCE). GOx was covalently immobilized onto GCNT modified GCE through the well known glutaraldehyde (GAD) chemistry. The immobilized GOx showed a pair of well-defined reversible redox peaks with a formal potential (E(0)') of -0.40V and a peak to peak separation (ΔE(p)) of 47mV. The surface coverage concentration (Г) of GOx in GCNT/GOx/GAD composite film modified GCE was 3.88×10(-9)mol cm(-2) which indicates the high enzyme loading. The electron transfer rate constant (k(s)) of GOx immobilized onto GCNT was 1.08s(-1) which validates a rapid electron transfer processes. The composite film shows linear response towards 6.30 to 20.09mM glucose. We observed a good sensitivity of 2.47μA mM(-)(1)cm(-2) for glucose at the composite film. The fabricated biosensor displayed two weeks stability. Moreover, it shows no response to 0.5mM of ascorbic acid (AA), uric acid (UA), acetaminophen (AP), pyruvate (PA) and lactate (LA) which shows its potential application in the determination of glucose from human serum samples. The composite film exhibits excellent recovery for glucose in human serum at physiological pH with good practical applicability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrochemical glucose biosensing by pyranose oxidase immobilized in gold nanoparticle-polyaniline/AgCl/gelatin nanocomposite matrix

0308-8146/$ see front matter 2009 Elsevier Ltd. A doi:10.1016/j.foodchem.2009.05.087 * Corresponding author. Tel./fax: +90 232 3438624 E-mail address: [email protected] (S. Timur). A novel pyranose oxidase (PyOx) biosensor based on gold nanoparticles (AuNPs)–polyaniline(PANI)/AgCl/ gelatin nanocomposite has been developed for the glucose detection. PyOx was immobilized on the surface of glass...

متن کامل

Immobilized enzyme-single-wall carbon nanotube composites for amperometric glucose detection at a very low applied potential.

The behaviour of support electrodes modified with randomly dispersed single-wall carbon nanotube meshes containing adsorbed glucose oxidase with respect to amperometric glucose detection at a low potential is demonstrated.

متن کامل

Electroanalytical sensing of Asulam based on nanocomposite modified glassy carbon electrode

In this study a facile approach to employ Copper nanoparticle (CuNPs) and multi-walled carbon nanotubes (MWCNT) as the nanomaterial for selective detection of asulam have been investigated. This work reports the electrocatalytic oxidation of asulam on glassy carbon electrodes (GCE) modified with multi-walled carbon nanotubes (MWCNT), ionic liquids (IL), chitosan (Chit) and copper nanoparticles ...

متن کامل

An efficient platform based on cupper complex-multiwalled carbon nanotube nanocomposite modified electrode for the determination of uric acid

A new voltammetric sensor for determination of uric acid (UA) by Cuppercomplex- multiwalled carbon nanotube (Cu-complex-CNT) nanocomposite modifiedcarbon paste electrode (CPE) is reported. The electrocatalytic behavior of theCu-complex-CNT nanocomposite modified CPE was studied in pH 2.0 phosphatebuffer solution by chronoamperometry (CA) and cyclic voltammetry (CV) in th...

متن کامل

Design and Fabrication of Glucose/O2 Enzymatic Biofuel Cell

Enzyme-based biofuel cells (EBFCs) are systems that use a variety of organic compounds to produce electricity through oxido-reductase enzymes, such as oxidase or dehydrogenase as biocatalysts immobilized on electrodes. In this study, a single-chamber EBFC consisting of carbon electrodes that operating at ambient temperature in phosphate buffer, pH 7 is reported. The EBFC anode was based on gluc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bioelectrochemistry

دوره 80 2  شماره 

صفحات  -

تاریخ انتشار 2011