Routine evaluation of BACTEC NR-16A and NR-17A media.

نویسندگان

  • R J Courcol
  • A V Durocher
  • M Roussel-Delvallez
  • A Fruchart
  • G R Martin
چکیده

The purpose of this study was to determine whether the BACTEC NR-16A and NR-17A media were more effective than the BACTEC NR-6A and NR-7A media in recovering organisms from the blood of patients undergoing antimicrobial therapy. A total of 986 sets of four blood culture bottles were compared, giving 141, 174, 93, and 104 isolates with BACTEC NR-6A, NR-16A, NR-7A, and NR-17A, respectively. BACTEC NR-6A and NR-7A media recovered 234 isolates, whereas BACTEC NR-16A and NR-17A media recovered 278 isolates. The recovery rate of bacteria when aerobic resin media were used was better than that with conventional aerobic media (P less than 0.001). The mean detection times were 51.5 and 69.7 h with NR-16A and NR-6A, respectively (P less than 0.01), whereas they were 68.2 and 71.3 h with NR-17A and NR-7A, respectively (P greater than 0.05). The small number of anaerobes recovered precluded a statistical comparison of relative recovery for that group of organisms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Bactec NR-660 and Signal systems.

Bactec NR-660, a computerised blood culture system using infrared analysis of microbial generated carbon dioxide, was compared with the Signal system, which detects gaseous pressure (due to bacterial metabolism) by a manometer. Four trials were undertaken: an in vitro evaluation of 99 bacteria in simulated blood cultures, and three prospective comparisons of a total of 2588 paired patient sampl...

متن کامل

Rapid detection of positive blood cultures with the BACTEC NR-660 does not require first-day subculturing.

An analysis of blood culture data was performed to determine whether subculturing within the first 24 h of incubation decreased the time to detection of positive blood cultures when compared with the routine use of the BACTEC NR-660 system (Johnston Laboratories, Inc., Towson, Md.). During a 9-month period (June 1985 to February 1986), 17,913 blood cultures were received in our laboratory, of w...

متن کامل

A comparison of costs and effectiveness of the BACTEC NR-730 system and a conventional method of blood culture.

Results and costs of the first six months experience with BACTEC NR-730 were compared with a series of blood cultures performed by the conventional method previously used. The newer technology detected the growth of 14.1% of significant isolates on the day of receipt of the specimens. The previous method lacked blind subcultures on the day of receipt and therefore detected growth only after ove...

متن کامل

Clinical comparison of isolator and BACTEC 660 resin media for blood culture.

The 10-ml Isolator system (E.I. du Pont de Nemours & Co., Inc., Wilmington, Del.) was compared with the BACTEC 16A-17A nonradiometric resin system (Johnston Laboratories, Inc., Towson, Md.) for isolation of organisms from 6,839 paired blood cultures. Equal volumes of blood (6 to 10 ml for each Isolator and 3 to 5 ml for each BACTEC bottle) were cultured in parallel in the two systems, and 600 i...

متن کامل

What is Nonreciprocity? – Part II

This paper is the second part of a two-part paper on Electromagnetic (EM) Nonreciprocity (NR). Part I has given a general definition of NR, pointed out that linear NR is a stronger form of NR than nonlinear (NL) NR, explained EM Time-Reversal (TR) Symmetry (TRS) Breaking (TRS-B), described linear Time-Invariant (TI) NR media, generalized the Lorentz reciprocity theorem for NR, and provided a ph...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 26 9  شماره 

صفحات  -

تاریخ انتشار 1988