Impact of guidewire selection and operator expertise on radiation exposure in transradial angiography

نویسندگان

  • Jianmin Yang
  • Ningfu Wang
  • Xiaoshan Tong
  • Xianhua Ye
  • Liang Zhou
  • Guoxin Tong
  • Yun Shen
  • Shuzheng Lv
چکیده

BACKGROUND Several studies have implied that the time of radiation exposure for patients and operators during the transradial approach for coronary angiography (TRA) is associated with the use of different guidewire or catheter and operator's finesse. This study aimed to assess the effects of non-hydrophilic or hydrophilic guidewire and operator expertise on fluoroscopy time and procedure time of TRA and further effects on the procedure safety. METHODS A total of 1035 consecutive patients undergoing TRA were recruited prospectively and respectively divided into non-hydrophilic guidewire and hydrophilic guidewire group, or well-experienced group and less-experienced group. The primary endpoints were fluoroscopy time and procedure time. Secondary endpoints included contrast volume, cost, guidewire exchange, switchover and complications . RESULTS TRA by non-hydrophilic guidewire group showed shorter fluoroscopy time and procedure time compared with hydrophilic guidewire group, similar results were found between well-experienced group and less-experienced group. Moreover, using of non-hydrophilic guidewire significantly reduced the incidence of hematoma and abnormal guidewie advancement, well-experienced group showed less dosage of contrast volume, lower incidence of radial artery spasm and frequency of guidewire exchange. CONCLUSIONS TRA by non-hydrophilic guidewire and well-experienced operator can decrease radiation exposure of patients and operators through reducing the fluoroscopy time and procedure time and further increase procedure safety. These will contribute to the optimization of TRA procedure and promote its widely application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Beam projections and radiation exposure in transradial and transfemoral approaches during coronary angiography

OBJECTIVE We aimed to compare the operator and patient radiation exposure in standard projections during elective diagnostic coronary angiography procedures via transradial (TRA) versus transfemoral (TFA) approaches. METHODS In this analytical cross-sectional study, a total of 202 consecutive patients who were candidates for diagnostic coronary angiography were randomized to undergo the proce...

متن کامل

Breast Radiation Protection in Coronary Angiography

Introduction: Coronary angiography (CA) is an interventional diagnostic procedure to assess cardiovascular disease. CA is performed using dedicated fluoroscopic systems equipped with either flat detector or image intensifier. There is an increase in the number of CA annually. Reducing the radiation exposure in the CA is essential, especially due to high fluoroscopy time. In ord...

متن کامل

Radiation exposure in relation to the arterial access site used for diagnostic coronary angiography and percutaneous coronary intervention: a systematic review and meta-analysis.

BACKGROUND Transradial access for cardiac catheterisation results in lower bleeding and vascular complications than the traditional transfemoral access route. However, the increased radiation exposure potentially associated with transradial access is a possible drawback of this method. Whether transradial access is associated with a clinically significant increase in radiation exposure that out...

متن کامل

Effectiveness of low rate fluoroscopy at reducing operator and patient radiation dose during transradial coronary angiography and interventions.

OBJECTIVES This study sought to determine the efficacy of low rate fluoroscopy at 7.5 frames/s (FPS) versus conventional 15 FPS for reduction of operator and patient radiation dose during diagnostic coronary angiography (DCA) and percutaneous coronary intervention (PCI) via the transradial approach (TRA). BACKGROUND TRA for cardiac catheterization is potentially associated with increased radi...

متن کامل

Transradial Neurointerventional Approach to Basilar Tip Aneurysm: Case Report and Technical Note

Cerebral angiography through transfemoral approach is preferred in most of the situation though in cardiovascular surgery transradial angiography is accounted as the superior standard. The present study aimed at presenting our early experience of transradial approach to cerebral angiography and intervention of a patient with basilar tip aneurysm that had inappropriate vasculature to perform rou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014