Magnetic resonance imaging and intraocular foreign bodies.

نویسندگان

  • P A Lagouros
  • B G Langer
  • G A Peyman
  • M F Mafee
  • D G Spigos
  • J Grisolano
چکیده

We conducted in vitro and in vivo experiments to study magnetic resonance imaging of intraocular foreign bodies. Diamagnetic and paramagnetic foreign bodies were imaged without artifact and without movement during the imaging process, while ferromagnetic foreign bodies produced large amounts of artifact that prevented meaningful images. All fetromagnetic foreign bodies moved during in vitro imaging. During in vivo imaging, three of four ferromagnetic bodies moved, producing substantial retinal injury. We concluded that magnetic resonance imaging is contraindicated in traumatized eyes with suspected ferromagnetic foreign bodies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metallic intraocular foreign body as detected by magnetic resonance imaging without complications– A case report

Purpose To describe a case and present unique images of a metallic intraocular foreign body that was identified in a 12-year-old male patient who underwent routine magnetic resonance imaging (MRI) to assess neurodevelopmental delay. Observations We present MRI and diagnostic imaging of a metallic intraocular foreign body in a young patient with no known history of trauma or reason for the exi...

متن کامل

Cataract formation after a magnetic resonance imaging (MRI) scan.

A 39-year-old man consulted his ophthalmologist with severe visual loss in the left eye, one day after a Magnetic Resonance Imaging (MRI) scan of his shoulder. The man worked in construction and was the victim of a serious accident with rib fractures and a pneumothorax 4 months earlier. He could not remember any eye injury. The examination by his ophthalmologist showed a visual acuity of 0.1 in...

متن کامل

Magnetic resonance imaging of feline eye

The purpose of this study was to investigate magnetic resonance imaging (MRI) of the normal feline eyeand optic nerves using T1-weighted and T2-weighted images. A total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. Magnetic resonance imaging data werecollected using GEMSOW (Philips) at a magnetic field strength of 1.5 T. Dorsal, sagittal, a...

متن کامل

Comparison among the imaging characteristics of the intravitreous wooden foreign body in rabbits

Objective: The intraocular foreign bodies (IOFBs) belong to the special ocular trauma. Diagnostic values (ultrasonography, CT/computed tomography and MRI/magnetic resonance imaging) of different imaging technologies for IOFBs in rabbit vitreous body were evaluated for clinical diagnosis. Methods: A total of 240 healthy rabbits were involved, 192 receiving the wooden IOFBs (f = 0.2 mm; different...

متن کامل

Chapter 16 MRI Issues for Implants and Devices

An important aspect of protecting patients from magnetic resonance imaging (MRI)related accidents and injuries involves an understanding of the risks associated with the implants, devices, and other objects (e.g., metallic foreign bodies) that may cause problems in this setting. This requires constant attention and diligence to obtain information and documentation about these items as part of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 105 4  شماره 

صفحات  -

تاریخ انتشار 1987