The three-dimensional scintillation dosimetry method: test for a 106Ru eye plaque applicator.

نویسندگان

  • A S Kirov
  • J Z Piao
  • N K Mathur
  • T R Miller
  • S Devic
  • S Trichter
  • M Zaider
  • C G Soares
  • T LoSasso
چکیده

The need for fast, accurate and high resolution dosimetric quality assurance in radiation therapy has been outpacing the development of new and improved 2D and 3D dosimetry techniques. This paper summarizes the efforts to create a novel and potentially very fast, 3D dosimetry method based on the observation of scintillation light from an irradiated liquid scintillator volume serving simultaneously as a phantom material and as a dose detector medium. The method, named three-dimensional scintillation dosimetry (3DSD), uses visible light images of the liquid scintillator volume at multiple angles and applies a tomographic algorithm to a series of these images to reconstruct the scintillation light emission density in each voxel of the volume. It is based on the hypothesis that with careful design and data processing, one can achieve acceptable proportionality between the local light emission density and the locally absorbed dose. The method is applied to a Ru-106 eye plaque immersed in a 16.4 cm3 liquid scintillator volume and the reconstructed 3D dose map is compared along selected profiles and planes with radiochromic film and diode measurements. The comparison indicates that the 3DSD method agrees, within 25% for most points or within approximately 2 mm distance to agreement, with the relative radiochromic film and diode dose distributions in a small (approximately 4.5 mm high and approximately 12 mm diameter) volume in the unobstructed, high gradient dose region outside the edge of the plaque. For a comparison, the reproducibility of the radiochromic film results for our measurements ranges from 10 to 15% within this volume. At present, the 3DSD method is not accurate close to the edge of the plaque, and further than approximately 10 mm (<10% central axis depth dose) from the plaque surface. Improvement strategies, considered important to provide a more accurate quick check of the dose profiles in 3D for brachytherapy applicators, are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo simulation of two 106Ru eye plaques in a new mathematical human eye model

  BEBIG Ruthenium-106 ophthalmic plaques have been used for treatment of uveal melanoma, retinoblastoma, melanoma of the iris and other special applications for many years. The plaques consist of a thin film of 106Ru, a beta emitter, encapsulated in pure silver. The present work proposes a new mathematical eye model for ophthalmic brachytherapy dosimetry. This new mod...

متن کامل

The measurement of three dimensional dose distribution of a ruthenium‐106 ophthalmological applicator using magnetic resonance imaging of BANG polymer gels1

The BANG (MGS Research Inc., Guilford, CT) polymer gel has been used as a dosimeter to determine the three-dimensional (3D) dose distribution of a ruthenium-106 (Ru-106) ophthalmologic applicator. An eye phantom made of the BANG gel was irradiated with the Ru-106 source for up to 1 h. The phantom and a set of calibration vials were scanned simultaneously in a GE 1.5 T MR imager using the Hahn s...

متن کامل

Calculation of beta-ray dose distributions from ophthalmic applicators and comparison with measurements in a model eye.

Dose distributions throughout the eye, from three types of beta-ray ophthalmic applicators, were calculated using the EGS4, ACCEPT 3.0, and other Monte Carlo codes. The applicators were those for which doses were measured in a recent international intercomparison [Med. Phys. 28, 1373 (2001)], planar applicators of 106Ru-106Rh and 90Sr-90Y and a concave 106Ru-106Rh applicator. The main purpose w...

متن کامل

Dosimetry Comparison of Water Phantom and Complete Eye Definition for 125I and 103Pd Brachytherapy Plaques

Introduction: In this paper, by complete definition of human eye containing the various parts and their materials, the difference between this model and a homogeneous water phantom are compared for two ophthalmic plaques using 125I and 103Pd. Material and methods: The simulation of the two phantoms were performed in the MCNP-4C code and by using the geometry of a three-dimensional eye, differen...

متن کامل

Ruthenium brachytherapy for uveal melanoma – single institution experience

Purpose The aim of this study was to report on results of uveal melanoma treatment with ruthenium-106 (106Ru) brachytherapy with long-term follow-up, in terms of local tumor control, eye retention rate, radiation retinopathy, and patients' survival. Material and methods Medical records of patients treated with ruthenium plaque due to uveal melanoma at the Department of Ophthalmology, Poznan U...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 50 13  شماره 

صفحات  -

تاریخ انتشار 2005