Dosimetric Quantities and Neutron Spectra Outside the Shielding of Electron Accelerators

نویسندگان

  • Alberto Fassò
  • James C. Liu
  • Sayed H. Rokni
چکیده

Typical neutron spectra as found at high energy electron accelerators outside concrete shielding of various thicknesses (at 90 degrees) have been calculated at three electron energies (100 MeV, 1 and 10 GeV) with the FLUKA Monte Carlo transport code. The results have provided useful information about neutron attenuation lengths and about the fraction of neutrons with energy larger than 20 MeV, not detectable by the usual radiation protection instruments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neutron Spectra and Dosimetric Quantities Outside Typical Concrete Shielding of Synchrotron Facilities

Neutron energy spectra at high energy electron accelerators outside concrete shielding of various thicknesses (30 to 240 cm at 65-95 degrees) have been calculated at three electron energies (100 MeV, 1 and 10 GeV) and an optimum Cu target of 30.48 cm long and 5.08 cm in radius with the FLUKA Monte Carlo code. Dose quantities such as the protection quantity of Effective dose E and the operationa...

متن کامل

Neutron Energy and Time-of-flight Spectra Behind the Lateral Shield of a High Energy Electron Accelerator Beam Dump, Part II: Monte Carlo Simulations

Energy spectra of high-energy neutrons and neutron time-of-flight spectra were calculated for the setup of experiment T-454 performed with a NE213 liquid scintillator at the Final Focus Test Beam (FFTB) facility at the Stanford Linear Accelerator Center. The neutrons were created by the interaction a 28.7 GeV electron beam in the aluminum beam dump of the FFTB which is housed inside a thick ste...

متن کامل

Neutron spectrometry with Bonner Spheres for area monitoring in particle accelerators.

Selecting the instruments to determine the operational quantities in the neutron fields produced by particle accelerators involves a combination of aspects, which is peculiar to these environments: the energy distribution of the neutron field, the continuous or pulsed time structure of the beam, the presence of other radiations to which the neutron instruments could have significant response an...

متن کامل

Unexpected dose and the biological effect of neutron contamination in linear accelerators

Employing High-energy photons in medical linear accelerators can lead to neutron contamination. The relative biological effect of neutrons is 20 times higher than photons. Consequently, its damage to the biological tissue is much higher and unobtrusive. In this study, we calculated neutron equivalent dose in a medical linear accelerator by the FLUKA Monte Carlo code system. The results show tha...

متن کامل

Monte Carlo calculation of shielding parameters for fast neutrons in newly developed heavy concretes

Introduction: The role of radiotherapy as a part of cancer management increases every year around the world. Thus, Radiation protection in the design of radiotherapy rooms are of great importance.   Materials and Methods: In present study using Monte Carlo method, MCNPX code, fourteen types of developed high density concretes with densities ranging from 2.45 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012