Effect of changes in oscillatory amplitude on PaCO(2) and PaO(2) during high frequency oscillatory ventilation.

نویسندگان

  • C Morgan
  • P R Dear
  • S J Newell
چکیده

AIMS To describe the relation between oscillatory amplitude changes and arterial blood gas (ABG) changes in preterm infants receiving high frequency oscillatory ventilation, using a multiparameter intra-arterial sensor (MPIAS). METHODS Continuous MPIAS ABG data were collected after amplitude changes and stratified according to FIO(2): high (> 0.4) or low (< 0.3). For each amplitude change, the maximum change (from baseline) in PaCO(2) and PaO(2) over the following 30 minutes was determined. In total, 64 oscillatory amplitude changes were measured in 21 infants (median birth weight 1040 g; gestation 27 weeks). RESULTS All amplitude increases produced PaCO(2) falls (median -0.98 and -1.13 kPa for high and low FIO(2) groups respectively). All amplitude decreases produced PaCO(2) rises (median +0.94 and +1.24 kPa for high and low FIO(2) groups respectively). About 95% of the change in PaCO(2) was completed in 30 minutes. Amplitude changes did not affect PaO(2) when FIO(2) > 0.4. When FIO(2) < 0.3, amplitude increases produced a PaO(2) rise (median = +1.1 kPa; P < 0.001) and amplitude decreases a fall (median = -1.2 kPa; P < 0.001). CONCLUSIONS After oscillatory amplitude changes, the speed but not the magnitude of the PaCO(2) change is predictable, and a rapid PaO(2) change accompanies the PaCO(2) change in infants with mild lung disease and a low FIO(2).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normocapnic high frequency oscillatory hyperventilation increases oxygenation in pigs.

High frequency oscillatory ventilation (HFOV), contrary to conventional ventilation, enables a safe increase in tidal volume (V(T)) without endangering alveoli by volutrauma or barotrauma. The aim of the study is to introduce the concept of normocapnic high frequency oscillatory hyperventilation and to assess its effect upon oxygen gain under experimental conditions. Laboratory pigs (n = 9) wer...

متن کامل

Effect of I/E ratio on mean alveolar pressure during high-frequency oscillatory ventilation.

This study investigated factors contributing to differences between mean alveolar pressure (PA) and mean pressure at the airway opening (Pao) during high-frequency oscillatory ventilation (HFOV). The effect of the inspiratory-to-expiratory time (I/E) ratio and amplitude of oscillation on the magnitude of - Pao (Pdiff) was examined by using the alveolar capsule technique in normal rabbit lungs (...

متن کامل

Respiratory Mechanics During High Frequency Oscillatory Ventilation : 1 A Physical Model and Preterm Infant Study

39 Accurate mechanics measurements during high frequency oscillatory ventilation (HFOV) 40 facilitate optimizing ventilator support settings. Yet, these are substantially influenced by 41 endotracheal tube (ETT) contributions which may dominate when leaks around uncuffed ETT 42 are present. We hypothesized that 1) the effective removal of ETT leaks may be confirmed via 43 direct comparison of m...

متن کامل

High-frequency oscillatory ventilation after cardiac surgery: a treatment for all ages

a recent issue of Critical Care, Bojan and colleagues [1] reported their experience with early initiation of high-frequency oscillatory ventilation (HFOV) in pediatric cardiac surgery that demonstrated shorter mechanical ventilation times and intensive care stays. Acute lung injury is common in adult patients undergoing surgery, yet there is scant reporting of the intraoperative utility of HFOV...

متن کامل

Damping of the dynamic pressure amplitude in the ventilatory circuit during high-frequency oscillatory ventilation.

The study deals with experimental measuring of attenuation of dynamic pressure during high-frequency oscillatory ventilation. The experimental circuit consists of high-frequency oscillatory ventilator Sensormedics 3100 B, patient circuit and lung model 5600i. Different values of the flow resistance and alveolar compliance were modelled during the experimental measurement. The ventilatory parame...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood. Fetal and neonatal edition

دوره 82 3  شماره 

صفحات  -

تاریخ انتشار 2000