Constrained Non-linear Elasticity Reconstruction Technique for Breast MRI Elastography

نویسندگان

  • A. Samani
  • I. Sack
  • D. Plewes
چکیده

A. Samani, I. Sack, D. Plewes University of Toronto, Sunnybrook and Women's College Health Sciences Centre, Toronto, Ontario, Canada Synopsis To increase the displacement SNR in breast MR elastography, tissues are compressed significantly. As a result, breast tissues undergo large deformations. This leads to significant geometric and material nonlinearities. In this study, methods for treating these nonlinearities are presented and their impact on elasticity reconstruction is investigated. For elasticity reconstruction, a constrained elastography method is used where tissues are treated as hyperelastic materials. The tissue hyperelastic parameters are calculated using inversion techniques with a nonlinear finite element (FE) model for forward modeling. Simulations indicate the feasibility of reconstructing the tissue hyperelastic parameters using displacement data with moderate SNR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Iterative Hyperelastic Parameters Reconstruction for Breast Cancer Assessment

In breast elastography, breast tissues usually undergo large compressions resulting in significant geometric and structural changes, and consequently nonlinear mechanical behavior. In this study, an elastography technique is presented where parameters characterizing tissue nonlinear behavior is reconstructed. Such parameters can be used for tumor tissue classification. To model the nonlinear be...

متن کامل

Constrained hyperelastic parameters reconstruction of PVA (Polyvinyl Alcohol) phantom undergoing large deformation

The nonlinear mechanical behavior of tissues that undergo large deformations, e.g. the breast, is characterized by hyperelastic parameters. These parameters take into account both types of nonlinearities: tissue intrinsic nonlinearity and geometric nonlinearity. Elastography technique capable of tissue hyperelastic parameter reconstruction has important clinical applications such as cancer diag...

متن کامل

Combined MRE and SPAMM tagged MRI for the analysis of large strain soft tissue mechanical properties

Introduction: Clinical conditions affecting soft tissue often present with altered mechanical properties (e.g. tumours, fibrosis and/or malignancy). Hence, the MRI based non-invasive analysis of soft tissue mechanical properties has been the focus of many fields of research. Soft tissue mechanical properties are nonlinear with respect to strain, strain-rate and frequency and, due to strain stif...

متن کامل

Utilizing a reference material for assessing absolute tumor mechanical properties in modality independent elastography

There is currently no reliable method for early characterization of breast cancer response to neoadjuvant chemotherapy (NAC) [1,2]. Given that disruption of normal structural architecture occurs in cancer-bearing tissue, we hypothesize that further structural changes occur in response to NAC. Consequently, we are investigating the use of modalityindependent elastography (MIE) [3-8] as a method ...

متن کامل

A constrained reconstruction technique of hyperelasticity parameters for breast cancer assessment.

In breast elastography, breast tissue usually undergoes large compression resulting in significant geometric and structural changes. This implies that breast elastography is associated with tissue nonlinear behavior. In this study, an elastography technique is presented and an inverse problem formulation is proposed to reconstruct parameters characterizing tissue hyperelasticity. Such parameter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002