The concentration of carbon monoxide in the breathing areas of workers during logging operations at the motor-manual level.

نویسنده

  • Krzysztof Leszczyński
چکیده

OBJECTIVES This article compares 2 variants of logging technologies at the motor-manual level: variant A - cutting and delimbing by means of a petrol chainsaw, skidding with the use of a cable winch mounted on a tractor (67-74 kW); variant B - cutting by means of a petrol chainsaw, skidding, debranching and cutting to length by means of a processor aggregated with a farm tractor (61 kW). MATERIAL AND METHODS Direct dosimetry and non-parametric (moving block bootstrap) methods were used in order to specify the characteristics of the collected sets. RESULTS Bootstrap average values show that the average CO concentration at a skidding tractor operator's station during early thinning was 2.54 mg×m(-3). At processor operator's station it amounted to 10.35 mg×m(-3). Such results allow to conclude that a higher CO concentration at the above-mentioned 2 work stations was observed during early thinning. In the case of a petrol chainsaw operator, it was observed that the permissible exposure limit (23 mg×m(-3)) was exceeded and the short-term permissible exposure limit (117 mg×m(-3)) was not. The average concentration value for a chainsaw operator working individually during late thinning interventions was substantially lower (15.01 mg×m(-3)), which results from the lack of technological pressure that can be observed while cooperating with a processor operator. CONCLUSIONS The risk increases along with conditions that generate the concentration of exhaust produced by 2-stroke petrol chainsaw engines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SMART ROOM CARBON MONOXIDE MONITORING AND CONTROL SYSTEM

Carbon Monoxide (CO) is the most abundant air pollutant gas and accumulates rapidly to dangerous concentrations even in areas that seem to be well ventilated. Carbon monoxide detectors/alarm systems exist but people who are old, hearing impaired, partially sighted or heavy sleepers may not get the warning or find it difficult to wake up and get out in the event of dangerous concentration of CO ...

متن کامل

Pnm-19: Residential Exposure to Carbon Monoxide and Spontaneous Abortion

Background: The relationship between air pollution exposure and adverse birth outcomes such as low birth weight and IUGR was studied. However, very few studies evaluated the effect of air pollution emissions on spontaneous abortion. We examined association between spontaneous abortion of the first trimester of pregnancy and ambient concentrations of carbon monoxide in Tehran. Materials and Meth...

متن کامل

روند یکساله میزان مواجهه رانندگان تاکسی شهر تهران با مونوکسیدکربن

  Background and Aim: Motor vehicles are an absolute necessity used extensively in all countries of the world. They are a major cause of air pollution with highly undesirable consequences. Thus, exposure to traffic pollution is a growing public health concern. Several studies indicate that people in the cabin of a vehicle inhale air with high concentrations of pollutants such as nitrogen oxides...

متن کامل

Monitoring and assessment of pollutants resulting from bench-blasting operations

Nitrogen oxides and carbon monoxide gases together with dust are known as the major pollutants arising during the blasting operations using the ammonium nitrate-fuel oil (ANFO) explosive at the Sungun surface mine, located in the northwest of Iran. The pollutants were monitored during some blasting operations at the mine. It was concluded that the gases and dust clouds initially went up to the ...

متن کامل

Modeling of carbon monoxide dispersion around the urban tunnel portals

The aim of this study is to investigate the problems caused by discharge of polluted air from tunnels into the environment with a specific focus on residential areas. In city tunnels, portal or stacks, pollutant management is a big challenge. Nowadays, air quality management, particularly in urban tunnels, is considered as a part of the ventilation system design. The goal is to see the environm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of occupational medicine and environmental health

دوره 27 5  شماره 

صفحات  -

تاریخ انتشار 2014