Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps
نویسندگان
چکیده
This paper presents the benefits in capacity and performance of a hybrid control of expansion valves for two 5-ton (17.6 kW) domestic heat pumps (HPs) based on experimental results. The hybrid control, as proposed by Kim et al. (2008a), employs a primary expansion valve that provides most of the pressure drop, while small secondary/balancing valves in the distributor lines to the circuits of the evaporator control the refrigerant flow to provide equal circuit exit superheats. Initial baseline data for Heat Pump 1 was taken with an electronic expansion valve. After that, secondary/balancing valves were inserted into the distributor lines and the same tests were repeated. Frost build-up tests at high outdoor humidity were conducted with Heat Pump 1 to determine the influence of the control scheme on the frost uniformity and system performance. For repeatable results, additional tests with partially blocked evaporator coils were done for both heat pumps. Heat Pump 2 was equipped with a vapor injected compressor and had two interchangeable evaporator coils of the same type. One of the evaporator coils was equipped with a more cost effective reduced hybrid control scheme and employed prototype 2-step balancing valves.
منابع مشابه
A Semi-Empirical Model for Studying the Impact of Thermal Mass and Cost-Return Analysis on Mixed-Mode Ventilation in Office Buildings
The heating capacity and coefficient of performance (COP) of conventional air-source heat pumps decreases towards lower ambient temperatures. Additionally, the heat pump stops running at very low ambient temperatures due to the high discharge temperature at the outlet of the compressor. Oil injected into the compression chamber absorbs the heat generated during the compression process and thus,...
متن کاملApplication Of Oil Flooded Compression With Regeneration To A Packaged Heat Pump System
The heating capacity and coefficient of performance (COP) of conventional air-source heat pumps decreases towards lower ambient temperatures. In addition, high discharge temperature at the compressor discharge might limit the operation of the heat pump at very low ambient temperatures. Oil injected into the compression chamber at the beginning of the compression process can absorb part of the h...
متن کاملEffects of Vapor Injected Compression, Hybrid Evaporator Flow Control, and Other Parameters on Seasonal Energy Efficiency
A companion paper (Bach et al. 2014) experimentally investigated the effects of vapor injected compression and hybrid evaporator flow control on capacity and COP. The goal of this paper is to provide insight into the effects of these technologies on heating seasonal performance (HSPF). HSPF was calculated using a modified version of the ANSI/AHRI 210/240 method, and parametric studies were perf...
متن کاملA Virtual EXV Mass Flow Sensor for Applications With Two-Phase Flow Inlet Conditions
In conventional vapor compression systems, electronic expansion valves (EXVs) are used for refrigerant flow control. Subcooled refrigerant enters the expansion device and is expanded to the evaporation pressure while the valve opening is modified to achieve the desired mass flowrate. The relationship between the inlet and outlet conditions, the opening, and the mass flowrate has been extensivel...
متن کاملامکانسنجی استفاده از مبدل بازیاب حرارت در سیکل تبرید تراکمی بخار با آنالیز ترمودینامیکی، انتقال حرارت و اقتصادی
Usually, it is common to use the internal heat exchanger subcooler-superheater after the condenser and before the expansion valve in the compression refrigeration cycles. In this study, the effect of the heat exchanger is evaluated by using recovery heat exchanger after the compressor and before the condenser. To this end, the vapor compression refrigeration cycle with conventional heat exchang...